摘要 采用3种不同工作方式引伸计对实验室拉伸试验机测量r值进行测量,通过对比异常曲线和异常值的具体表现,认定r值异常曲线除了与试验宽度方向的形状公差以及表面粗糙度以及试样装夹时的对中度有关外,主要原因是宽度引伸计跟踪异常。宽度方向曲线是否出现突变和跃升与宽度引伸计的机械结构密切相关;当宽度引伸计机械结构异常时,测量的拉伸曲线将出现突变和跃升,严重影响r值测量的准确性。对比机械引伸计与光学引伸计,光学引伸计不与试样接触,可以保证宽度方向的变形跟踪正常,从而保证r值测量的准确性和重复性。 Different working modes were used to measure the r-value measured by the laboratory tensile testing machine.By comparing the specific performance of the abnormal curve and the abnormal value,it was concluded that the abnormal curve of r-value was related to the shape tolerance of the width direction of the test,the surface roughness and the moderation of the sample when clamped.The main reason was the abnormal tracking of the width extensometer.Whether there is a sudden change or jump in the width direction curve is closely related to the mechanical structure of the width extensometer.When the mechanical structure of the width extensometer is abnormal,the measured tensile curve will appear sudden change and jump,which seriously affects the accuracy of r-value measurement.Compared with mechanical extensometers and optical extensometers,optical extensometers are not in contact with the sample,which can ensure the normal tracking of deformation in width direction,thus ensuring the accuracy and repeatability of r-value measurement.
作者 孙志鹏 徐雁 宋祖峰 SUN Zhi-peng;XU Yan;SONG Zu-feng(Technology Center,Maanshan Iron and Steel Co.,Ltd.,Ma'anshan 243000,China)
出处 《物理测试》 CAS 2020年第1期24-27,共4页 Physics Examination and Testing
关键词 r值 宽度引伸计 测量准确性 r-value width extensometer measurement accuracy
  • 相关文献

参考文献10

二级参考文献27

  • 1谭新常,黄义宏,刘树桢.关于塑性应变比的测定[J].金属成形工艺,1994,12(2):85-88. 被引量:7
  • 2李赛毅,张新明,陈志永.应变水平对铝镇静钢板塑性应变比的影响[J].钢铁研究学报,1996,8(5):48-51. 被引量:5
  • 3张卓.室温拉伸试验过程中拉伸速率的控制[J].物理测试,2006,24(4):61-62. 被引量:8
  • 4GB/T5027-1999,金属薄板和薄带塑性应变比(r值)试验方法[S].
  • 5GB/T5027-2007 金属材料薄板和薄带塑性应变比(r值)的测定[S].
  • 6ISO 10113 : 2006 Metallic Materials-Sheet and Strip- Determination of Plastic Strain Ratio[S].
  • 7Danckert J, Nielsen K B. Determination of the plastic anisotropy r in sheet metal using automatic tensile test equipment[J]. Journal of Materials Processing Technology, 1998, 73:276-280.
  • 8Gg/T5027-2007金属材料薄板和薄带塑性应变比(r值)的测定.
  • 9ISO 10113. 2006 Metallic materials sheet and strip determination of plastic strain ratio[.S.
  • 10GB/T 5028-1999.金属薄板和薄带拉伸应变硬化指数(n值)试验方法[S],1999.

共引文献37

同被引文献7

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部