离子色谱法测定农村饮水中痕量溴酸盐的研究 被引量:7

Determination of Bromate in Drinking Water by Using Ion Chromatography
下载PDF
导出
摘要 建立了一种简便的用离子色谱测定水中痕量溴酸盐的方法。通过银电极电解方法,除去水样中干扰溴酸根测定的氯离子,并应用微波浓缩水样后,在一定的色谱条件下测定水样中溴酸根离子的含量,检出限可达5μg.L-1。 There are more and more concerns about bromate in the drinking water due to their potential adverse effects to human health.A simple technique for the determination of trace level of bromate in drinking water by using ion chromatography is presented.In the selected concentration and velocity of the sodium hydroxide eluent,bromate and other anions can be separated with the Dionex DX-120 IC machine and the IonPac As16 anion-exchange column in linear gradient.Prior to ion chromatography,the drinking water sample was treated with electrolyzing argentine electrode to minimize the disturbance of superfluous chloride and then concentrated in a microwave oven in 10 minutes.The detection limit of this method for the bromate is 5μg·L^(-1),and the recoveries for bromate are greater than 60%.The method can be applicable for the detection of bromate in drinking water.
出处 《农业环境科学学报》 CAS CSCD 北大核心 2005年第z1期263-267,共5页 Journal of Agro-Environment Science
关键词 溴酸根离子 离子色谱法 饮用水 bromate ion chromatography drinking water
  • 相关文献

参考文献10

  • 1欧阳红,马军.离子色谱法测定饮用水中微量无机消毒副产物——ClO_2^-、ClO_3^-和BrO_3^-[J].哈尔滨建筑大学学报,2001,34(4):70-73. 被引量:7
  • 2[2]Application Note 81, Ion chromatographic determination of oxyhalides and bromide at trace level concentrations in drinking water using direct injection. 1997. Dionex Corporation, Sunnyvale, CA, USA.
  • 3[3]Jackson L K, Joyce R J, Laikhtman M, et al. Determination of trace level bromate in drinking water by direct injection ion chromatography [ J ].Chromatogr A, 1998,829:187 - 192.
  • 4[4]Wagner H. P. , Pepich B. V. Determination of inorganic oxyhalide disinfection by - products in drinking water using ion chromatography with the addition of a post - column reagent for trace bromate analysis. U.S.Environmental Protection Agency Method 317, 2; Cincinnati, Ohio,2001.
  • 5[5]Delcomyn C A, Weinberg H S, Singer P C Use of ion chromatography with post - column traction for the measurement of tribromide to evaluate bromate levels in drinking water [ J ]. Chromatogr A, 2001,920:213 -219.
  • 6[6]Echigo S, Minear R A, Yamada H, et al, Comparison of post - column reaction methods for the analysis of bromate and nitrite in drinking water[ J ]. Chromatogr A, 2001,920: 205 - 211.
  • 7[7]Creed J T, Magnuson M L, Brockhoff C A. Determination of bromate in the presence of brominated haloacetic acids by ion chromatography with inductively coupled plasma mass spectrometric detection [ J ]. Environ Sci Technol,1997, 31 (7): 2059 -2063.
  • 8[8]Pantsar - Kallio M, Manninen P K G. Speciation of halogenides and oxyhalogens by ion chromatography inductively coupled plasma mass spectrometry[ J]. Anal Chem Acta, 1998,360:161 - 166.
  • 9[9]Creed J T, Brockhoff C A. Isotope dilution analysis of bromate in drinking water matrixes by ion chromatography with inductively coupled plasma mass spectrometric detection[ J ]. Anal Chem, 1999,71 ( 3 ): 722 -726.
  • 10[10]Roehl R, Slingsby R, Avdalovic N, et al. Application of ion chromatography with electrospray mass spectrometric detection to determination of environmental contaminants in water [ J]. Chromatogr A, 2002, 956:245 - 254.