期刊文献+

血清半胱氨酸蛋白酶抑制剂C检测对诊断早期肾功能损害的价值 被引量:17

下载PDF
导出
摘要 目的:探讨血清半胱氨酸蛋白酶抑制剂C(Cys C)水平检测对高血压、糖尿病早期肾功能损害的诊断价值。方法:收集22例高血压病、28例糖尿病及44例肾病患者的血清标本,用酶法测定血清肌酐、尿素氮,用颗粒增强免疫比浊法测定血清CysC,放射免疫法测定β2-微球蛋白。结果:高血压病及糖尿病两组患者血清Cys C和β2-微球蛋白的异常检出率显著高于血清肌酐、尿素氮;高血压病及糖尿病两组患者血清Cys C水平均较正常对照组明显升高(P<0.01);肾病组各项检测指标均显著高于高血压病组、糖尿病组和正常对照组。结论:对早期肾功能损害的诊断,血清Cys C测定敏感性稍低于β2-微球蛋白,但其特异性优于血清β2-微球蛋白,血清Cys C可作为高血压病及糖尿病早期肾功能损害的辅助诊断指标之一。
作者 覃文周
出处 《广西医学院学报》 北大核心 2008年第3期445-446,共2页
  • 相关文献

参考文献6

  • 1[1]GrubbA,Simonsen O,Stfeit G,et al.Serum concentration of cystatin C,factor Dand β2-microglobulin as a measure of glomerularfiltration rate[J].Acta Med Scand,1985,218:499.
  • 2李海霞,吴红花,徐国宾,郭晓蕙,夏铁安.血清半胱氨酸蛋白酶抑制剂C与肌酐在评价糖尿病患者肾小球滤过功能中的比较研究[J].中华检验医学杂志,2005,28(6):602-605. 被引量:107
  • 3[4]MojiminyiOA,AbdellaN,GeorgeS.Evaluation ofserumcystatin Candchromogranin Aasmarkersof nep hrop athyin p atien tswithtyp e2diabetesmellitus[J].ScandJClin LabInvest,2000,60(6):483.
  • 4[5]RischL,BlumbergA,HuberAR,et al.Assessmentofrenalfunction in renaltransp lantp atientsusingcystatinc,acomp arison tootherrenalfunction markersandestimates[J].RenalFailure,2001,23(3&4):439.
  • 5[6]JovanovicD,Krstivojevic P,ObradovicI.Serumcystatin Cand β2-microglobulin asmarkersofglomerularfiltration rate[J].RenalFailure,2003,25(1):123.
  • 6孙红,陈莎,段艺,艾洪武,胡红兵,游上游.血清胱抑素C在儿童肾脏疾病中的应用研究[J].微循环学杂志,2005,15(4):31-32. 被引量:40

二级参考文献13

  • 1胡亚美 江载芳.诸福棠实用儿科学:第七版[M].北京:人民卫生出版社,2002.550-552.
  • 2Meir P, Froidevaux C. Cystatin C concentration and glomerular filtration rate. Lancet, 2001,357(9256):634~635.
  • 3Coll E, Botey A. Serum Cystatin C as a new marker for noninvasive estimation of glomerular filtration rate and as a marker for early renal impairment.Am J Kidney Dis, 2000,36(1): 29~34.
  • 4周玉红 左力 王梅.MDRD方程预测肾小球滤过率的临床应用评价[J].中华肾脏病杂志,2004,20:30-34.
  • 5Randers E, Erlandsen EJ. Serum Cystatin C as an endogenous marker of the renal function - a review. Clin Chem Lab Med , 1999,37:389-395.
  • 6Mojimintyi OA, Abdella N, George S. Evaluation of serum cystatin C and chromogranin A as markers of nephropathy in patients with type 2 diabetes mellitus. Scand J Clin Lab Invest, 2000, 60:483-489.
  • 7Oddoze C, Morange S, Portugal H, et al. Cystatin C is not more sensitive than creatinine for detecting early renal impairment in patients with diabetes. Am J Kidney Dis, 2001,38:310-316.
  • 8Dharnidharka VR,Kwon C,Stevens G. Serum Cystatin C is superior to serum creatinine as a marker of kidney function:a meta-analysis. Am J Kidney Dis, 2002,40:221-226.
  • 9Levey AS,Bosch JP,Lewis JB, et al. A more accurate method to estimate glomerular filtration rate from serum creatinine:a new prediction equation. Ann Intern Med, 1999,130:461-470.
  • 10方炜.肾小球滤过率的检测及进展[J].国外医学(泌尿系统分册),1997,17(4):178-180. 被引量:25

共引文献141

同被引文献143

引证文献17

二级引证文献165

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部