期刊文献+

全程瞬变电磁系统的浅层探测实验研究 被引量:6

Study of the Experiments of All-time Tramsient Electromagnetic System for Shallow Survey
下载PDF
导出
摘要 介绍了全程瞬变电磁ATTEM系统的基本原理及组成。采用该系统在长春市秦家屯进行了模型实验和活断层勘探实验,并与常规瞬变电磁系统ATEM-Ⅱ的勘探结果对比。实验结果表明,ATTEM系统具有很好的浅层探测能力,在该地区其最浅有效探测深度为地下1~2m。 The basic principle and structure of All-time transient electromagnetic(ATTEM) system are introduced.Model experiments and field experiments were performed in Changchun Qinjiatun using ATTEM,the interpretation results show that ATTEM has better shallow sounding ability than traditional transient electromagnetic system,such as ATEM-II,and the least sounding depth of ATTEM in the area is about 1 to 2 meters.
出处 《吉林大学学报(地球科学版)》 EI CAS CSCD 北大核心 2005年第S1期95-98,共4页 Journal of Jilin University:Earth Science Edition
基金 国家自然科学基金项目(40127003)
关键词 ATTEM ATEM-II 瞬变电磁 浅层探测 ATTEM ATEM-II transient electromagnetic shallow sounding
  • 相关文献

参考文献3

二级参考文献7

  • 1Bai Denghai,Proceedings to the 15th EM Workshop,2000年
  • 2蒋邦远(JIANG Bang-yun). 实用近区磁源瞬变电磁法勘探(Applied Near Zone Magnetic Source Transient Electromagnetic Exploration )[M].北京:地质出版社( Beijing: Geological Publish House),1998.
  • 3McCracken K G,Oristalio M L,Hohmann G W. Minimization of noise in electromagnetic exploration systems[J]. Geophysics, 1986,51(3): 819-832.
  • 4Neri B,Pellegrini B,Saletti R. Ultra low-nose preamplifier for low-frequency noise measurements in electron devices[J]. IEEE Trans Instrum Meas, 1996,40(1):2-6.
  • 5戴逸松(DAI Yi-song). 微弱信号检测方法及仪器( Weak Signal Acquisition and Instrument) [M].北京:国防工业出版社(Beijing: National Defence Industry Publishing House), 1994.
  • 6王淑玲 (WANG Shu-ling). 基于浮点放大的瞬变电磁接收机的研制( The Development of Transient Electromagnetic Methods Receiver Based on Floating Point Amplification)[D].长春:吉林大学硕士学位论文(Changchun: the master's degree thesis of Jilin University),2001.
  • 7袁真,李海.低噪声运放前置放大器的实用设计[J].仪表技术,2000(6):20-22. 被引量:8

共引文献80

同被引文献61

引证文献6

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部