分析了电网谐波功率潮流方向对其安装的无源滤波器和有源滤波器的影响,证明了只有根据电网谐波功率潮流的方向和谐波源类型来确定所使用的滤波器及其工作方式才能达到预期的滤波效果。
This paper analyzes how direction of harmonic power flow affects the installed active power filter and passive power filter,and proves that the expected effect of filter can only be guaranteed by selecting appropriate filter and its work pattern in accordance with the direction of harmonic power flow and the type of harmonic source.
出处
《黑龙江电力》
CAS
2010年第3期193-195,218,共4页
Heilongjiang Electric Power