摘要
文章提出了农网改造后农村进行低压无功补偿的必要性,以及对采用何种具体的补偿方式进行了探讨;详细介绍了两个无功就地平衡降损实例,并对降损效果进行了分析;指出在新形势下县级供电企业应把无功补偿工作的重点放在低压电网。
This paper puts forward the necessity of low voltags reactive power compensation after rural network retrofit, and discusses the way of compensation. Two examples of local reactive power balancing are introduced in detail, and the effects of reduced loss are analyzed. It is pointed out that under the new situation, the focal point of reactive power compensation for the power supply enterprises of county - level should be taken in low vohags power network.
出处
《电力设备》
2004年第9期57-58,共2页
Electrical Equipment
关键词
农电
低压降损
低压无功补偿
无功就地平衡降损法
rural electricity
reduced loss of tow voltags
low voltage reactive power compensation
reduced loss method of local reactive power balancing