期刊文献+

影响实用化实时测温系统测温精度的几个因素 被引量:2

SEVERAL FACTORS OF INFLUENCING MEASUREMENT ACCURACY FOR A PRACTICAL REAL-TIME TEMPERATURE MEASUREMENT SYSTEM
下载PDF
导出
摘要 基于Kirchhoff定律 ,利用半导体激光器及钽酸锂热释电探测器设计了一种实用化的实时测温系统 .从待测目标表面的红外辐射特性、待测表面周围的其它辐射体、大气的透射特性以及测温系统本身这四个方面出发 ,对影响该系统测温精度的因素进行了详尽分析 ,并提出了提高测温精度的相应措施 .实验结果表明 ,在测温范围 6 73~14 73K内 ,温度测量的不确定度在 0 .3%以内 ,符合设计要求 . Based on the Kirchhoff law, a practical temperature real-time measurement system using laser diode and LiTaO3 pyroelectric detector was developed. According to the infrared radiation characteristics of the measurement surface, surroundings, transmission features of atmosphere and the temperature measurement system itself, detailed analyses were given on the factors of influencing temperature measurement accuracy. And the measures on improving the temperature measurement accuracy were put forward. Experimental results show that the temperature measurement inaccuracy is within 0. 3%, and it is suitable for the requirements.
出处 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2004年第5期396-400,共5页 Journal of Infrared and Millimeter Waves
基金 河南省科技攻关计划 ( 0 0 112 0 3 2 1)
关键词 测温精度 透射特性 半导体激光器 红外辐射特性 热释电探测器 Kirchhoff定律 测温系统 测温范围 钽酸锂 温度测量 temperature measurement by radiation temperature measurement inaccuracy temperature measurement sensitivity pyroelectric detector laser diode
  • 相关文献

参考文献7

二级参考文献34

  • 1[1]Khan M A, Allemand C, Eagar T W. Noncontact temperature measurement Ⅰ:interpolation based techniques. Rev.Sci.Instrum., 1991, 62(2): 392-402
  • 2[2]Hahn J W, Rhee C. Reference wavelength method for a two-color pyrometer. Applied Optics, 1987, 26(24): 5276-5279
  • 3[3]Hunter G B, Allehand C D, Eager T W. Multiwavelength pyrometer Opt.Eng., 1985, 24(6): 1081-1085
  • 4[4]Krivtzum V,Grass B, Hergenroder R, et al. Temperature measurement of liquids by differential absorption of two diode laser: Application of contactless optical detection in isotachophoresis. Applied Spectroscopy, 2001, 55(9): 1251-1258
  • 5[6]Fan C H, Longtin J P. Laser-based measurement of temperature or concentration change at liquids surfaces. Journal of Heat Transfer, Transactions ASME, 2000, 122(4): 757-762
  • 6[7]Dewitt D P. Inferring temperature from optical radiation measurement. Opt. Eng., 1986, 25(4): 596-601
  • 7M A Khan, C Allemand, T W Eagar. Noncontact temperature measurement I : interpolation based techniques [J]. Rev. Sci. Instrum , 1991, 62(2):392-402.
  • 8J W Hahn, C Rhee. Reference wavelength method for a two-color pyrometer [J]. Appl. Opt , 1987, 26(24) :5276-5279.
  • 9G B Hunter, C D Allemand, T W Eagar.Multiwavelength pyrometer: an improved method [J].Opt. Eng., 1985, 24(6):1081-1085.
  • 10V Krivtzum, B Grab, R Hergenroder et al..Temperature measurement of liquids by differential absorption of two diode lasers: Application of contactless optical detection in isotachophoresis [ J ]. Appl.Spectroscopy. 2001, 55(9) : 1251-1258.

共引文献30

同被引文献9

引证文献2

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部