根据中压配电网的结构特点引入数据结构中邻接表来保存配电网拓扑结构。介绍了邻接表的形成方法和结构特点。给出了用邻接表保存配电网拓扑结构的实现程序以及运行方式改变后进行拓扑结构再分析的方法。用邻接表保存中压配电网的拓扑结构,大大缩短了潮流的计算时间。
According to the characters of mid-voltage distribution system,the adjacency list of data structure is introduced to save its topology structure. The formation and structural features of adjacency list are described. The implementation program is provided,and the reanalysis method of topology structure after operation pattern change is offered. Using adjacency list to save topology structure in power flow calculation,the calculation time is greatly reduced.
出处
《电力自动化设备》
EI
CSCD
北大核心
2005年第3期57-59,共3页
Electric Power Automation Equipment
关键词
邻接表
快速
潮流计算
adjacency list
fast