7Eaton AC, Francis RN. The provision of transurethral prostatectomy on a day-case basis using bipolar plasma kinetic technology. BJU International, 2002, 89 (6):534-537.
二级参考文献19
1[1]Mcbust W K,Holtgrewe H L,Cockett A T K,et al.Transurethral prostatectomy; Immediate and postoper ative complications. Axooperative study of thirteen par ticipating institution evaluating 3885 patients . J Urol,1989,141: 243- 247.
2[2]Evans J, Singer M,Coppinger S, et al. Cardiovascular performance and core temperature during transurethral prostatectomy. J Urol, 1994,152,2025 2028.
3[3]Freedman M, van Molen S W, Makings E. Blood loss measurement during transurethral resection of the prostate gland. Br J Uro1,1985,57:311-314.
4[4]Ekengren J ,Hahn R G. Blood loss during transurethral resection of the prostate as measured by the hemochrome photometer. J Urol, 1993,42: 501 - 505.
5[5]Narayan P,Tewari A, Croker, et al. Factors affecting sizes and configuration of electrovaporization lesions ing th the prostate. J Uro1,1996,47:679-683.
6[6]Elengren J, Hmhn R G. Complications during transurethral aporization. Urology, 1996,48: 424- 427.
7[7]Henry B,Barre P. Electro-vaporisation of the prostate with the gyrus device. Eur Urol, 2000,37 (Suppl 2): 1 -175.
8[8]Virdi,Faiyaz K, Ponnambalam Chandrasekar, et al. A prospectiverandomised study between transurethral va porisation using plasmakinetic energy. J Urol , 163(Suppl) :268-271.
9[9]Lefaucheur J P, Yiou R,Salomon L,et al. Abbou-CC assessment of penile small nerve fiber damage after transurethral resection of the prostate by measurement of penile thermal sensation. J Urol,2000, 164: 1416-1419.
10Holtgrewe HL.Current trends in management of men with lower urinary tract symptoms and benign prostatic hyperplasia.Urology,1998,51(suppl 4A):1-7.
3Mebust WK, Holtgrewe HL, Cockett ATK, et al. Transurethral prostatectomy: immediate and postoperative complications. A cooperative study of 13 participating institutions evaluating 3885 patients. J Urol, 1989, 141: 243
4Botto H, Lebret T, Barre P, et al. Electrovaporization of the prostate with the Gyrus device. J Endourol, 2001, 15(3): 313
5Eaton AC, Francis RN. The provision of transurethral prostatectomy on a day-case basis using bipolar plasma kinetic technology. BJU Int, 2002, 89(6):534
6Dincel C, Samli MM, Guler C, et al. Plasma kinetic vaporaization of the prostate: clinical evaluation of a new technique. J Endourol, 2004, 18(3): 293
7Dnasmuir WD, McFarlane JP, Tan A, et al. Gyrus bipolar electroviporization vs transurethral resection of the prostate: a randomized prospective single-blind trial with 1 y follow-up. Prostate Cancer Prostatic Dis, 2003, 6(2): 182