期刊文献+

X射线皮秒分幅相机在强X射线情况下的应用研究 被引量:3

Application of the X-Ray Picosecond Framing Camera in Intense X-Ray Pulse
原文传递
导出
摘要 扫描型变象管X射线皮秒分幅相机在强X射线情况下,由于空间电荷效应,像质变坏,甚至无法工作。本文简述了MgF2光阴极材料的性能,首次在X射线皮秒变象管分幅相机上的应用结果:降低了强X射线源情况下分幅管内空间电荷效应的影响,并获得了清晰的物理图象。 Image distortion of the electro-optical tube X-ray framing camera becomes serious for intense X-ray pulse operation because of the space charge effect. This paper describes the characteristic of MgF2 photocathode and its first application in the framing camara. The space charge effect has been reduced and the clear pictures have been obtained for the intense X-rays.
出处 《光学学报》 EI CAS CSCD 北大核心 1995年第12期1738-1740,共3页 Acta Optica Sinica
基金 中国工程物理研究院院基金
关键词 皮秒分幅相机 软X射线 激光核聚变 摄影机 picosecond framing camera, soft X-ray, laser fusion.
  • 相关文献

参考文献2

二级参考文献2

  • 1常增虎,侯洵,张小秋,龚美霞,牛丽宏,雷志远,杨宏儒,刘秀琴.X射线皮秒变象管分幅相机研究[J]高速摄影与光子学,1988(01).
  • 2牛憨笨,张焕文,杨勤劳,赵积来,高继魁,郭宝平,赵慧娟,宋宗贤,李齐湘,刘元群,高山.变像管皮秒分幅和飞秒扫描相机的实验研究[J].光子学报,1992,21(1):11-20. 被引量:5

共引文献2

同被引文献34

  • 1江孝国,王远,张开志,郭宝平,石金水,李成刚.高速分幅成像系统中多路图像性能不一致的校正方法研究[J].光学学报,2006,26(4):531-535. 被引量:6
  • 2林尊琪 何兴法 林康春 等.我国首台皮秒级X射线分幅相机试用成功.中国激光,1991,18(8):639-640.
  • 3D. K. Bradley, P M. Bell, J. D. Kilkenny. High-speed gated X-ray imaging for ICF target experiment[J]. Rev. Sci. Instrum., 1992, 63(10): 4813-4817.
  • 4Bing Shan, Takeshi Yanagidaira, Katsuji Shimoda et al.. Quantitative measurement of X ray images with a gated microchannel plate system in a Z-pinch plasma experiment[J]. Rev. Sci. Instrum. , 1999, 70(3): 1688-1693.
  • 5Jinyuan Liu, Lihong Niu, Wenda Peng et al.. Application of a fast electrical pulse in gated multichannel plate camera[J-. Rev. Sci. Instrum. , 2007, 78(5): 055104.
  • 6Houzhi Cai, Jinyuan Liu, Lihong Niu et al.. Monte Carlo simulation for microchannel plate framing camera [ J ]. Opt. Eng., 2010, 49(8): 080502.
  • 7John A. Oertel, Robert Aragonez, Tom Archuleta et al.. Gated X-ray detector for the national ignition faeility[J]. Rev. Sci. lnstrum. , 2006, 77(10) : 10E308.
  • 8Houzhi Cai, Jinyuan Liu, Lihong Niu et al.. Non-gain microchannel plate gated framing camera [J]. Rev. Sci. Instrum. , 2011, 82(5) : 056102.
  • 9M. J. Eckart, R. L. Hanks, J. D. Kilkenny et al. Large-area 200-ps gated microchannel plate detector [J]. Rev. Sci. Instrum. , 1986, 57(8) : 2046-2048.
  • 10J. D. Kilkenny, P. Bell, R. Hankset al.. High speed gated X rayimagers[J]. Rev. Sci. Instrum., 1988, 59(8): 1793-1796.

引证文献3

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部