采用厌氧/好氧生物脱氨-絮凝法处理焦化废水,出水中NH_3-N<15mg/L,COD为96-158mg/L。利用甲醇残液及其他有机废水作为外加碳源,可以达到以废治废的目的。
Coking-plant wastewater can be treated by anaerobic/aerobic(A/O)process fOrbiological removal of nitrogen,followed by flocculation process with polymerized ferricsulfate as flocculant,resulting in NH_3-N<15mg/L and COD: 96-158mg/L in the effluent.Methanol residue or other organic wastewater can be used as supplemental carbon sourcesfor denitrification process.