摘要 目的对三种内固定方法治疗髋臼骨折进行生物力学比较,为临床选择内固定方法提供可靠的实验依据。方法将12个半骨盆随机编号,分成A、B、C三组。A组给予后柱表面张力带钢丝内固定;B组给予经髋臼顶至前柱拉力螺丝钉内固定;C组给予后柱骨盆重建单钢板固定。在CSS-44020型电子万能试验机上进行该试验。结果将三组生物力学测定的最后结果进行统计学分析,将三组所测的最后结果(-x±s,KN):张力带0.436±0.067,螺钉0.406±0.068,钢板0.670±0.158,经SAS6.12(Stata4.0)进行统计学分析。结论实验结果和临床效果疗效分析相一致,证明骨盆骨折内固定生物力学测试实验具有较高的精确度,同时说明实验结果有参考的价值。 Objective To provide experimental data for the internal fixation of acetabulum fractures by biomechanical comparison of three internal fixation methods. Methods Twelve half pelvises were classified into 3 groups randomly. Different methods were used respectively. In group A, the internal fixation was with tension band wiring at posterior column. In group B, it was with compressionscrew from the top of acetabulum to anterior column. In group C, the fixation was with curved reconstruction plates at posterior column. The universal CSS- 44020 electronic testing machine was used in the experiment. Results The tensile forces were 0.436 ± 0.067, 0.406 ± 0.068, and 0. 670 ± 0. 158 respectively, Conclusion The experimental results agree with the clinical observation, which prove that biomechanical measurement is accurate, and deserve the reference.
出处 《中国骨与关节损伤杂志》 2005年第8期508-509,共2页 Chinese Journal of Bone and Joint Injury
  • 相关文献

参考文献4

  • 1钟广玲,刘效仿,陈志维,余海波,杨匡洋.复杂髋臼骨折的手术治疗[J].骨与关节损伤杂志,2000,15(3):167-169. 被引量:16
  • 2王庆贤,张英泽,潘进社,彭阿钦,宋连新,李志.髋臼横断骨折两种内固定方式的生物力学研究[J].骨与关节损伤杂志,2001,16(1):33-34. 被引量:10
  • 3Speringer ER, Lachiewicz PF, Gillbert JA. Internal fixation of femoral neck fractures: a comparative biomechanical study of knowles pins and 6.5 mm cancellous screws. Clin Orthop, 1991, 267:85.
  • 4Matta JM. Fractures of the acetabulum; accuracy of reduction and clinical results in patients managed operatively with three weeks after the injury. J Bone Joint Surg (Am), 1996, 28:163.

二级参考文献13

  • 11,Johe Wey,Doreen Dipadquale,Louis Levitt et al.Operative treatment of acetabular fracture through the extensile Henry approach.J Trauma,1999,46:255
  • 22,Mayo KA.Open reduction and internal fixation of fractures of the acatabulum,Clin Orthop,1994,305:31
  • 33,Matta JM.Fractures of the acetabulum;accuracy of reduction and clinical results in patients managed operatively with three weeks after the injury.J Bone Joint Surg(Am),1996,28:163
  • 44,Brooker AF,Bowerman JW,Robinson RA et al.Ectopis assification following total hip replacement;incidence and a method of classification.J Bone Joint Surg(Am),1973,55:1629
  • 55,Alonson JE,Davila R,Bradley E et al.Extended iliofemoral Versus Triradiate approaches in management of associated acetabular fractures.Clin Orthop,1994;305:81
  • 66,Calder HB,Mast J,Johnstone C et al.intraoperative evoked potential monitoring in acetabular surgery,Clin Orthop,1994,305:160
  • 77,Helfet DL,Anand N,Malkani All et al.Intraoperative monitoring of motor pathmays duing operative fixation of accute acetabular fractures.J Othop Trauma,1997,11:26
  • 88,Gholambor N,Matta JM,Bernstein et al.Heterotopic ossification following operative treatment of acetabular fracture.Clin Orthop,1994,305:96
  • 9[1]Springer ER, lachiewicz PF, Gilbert JA. Internal fixation of femoral neck fractures: a comparative biomechanical study of knowles pins and 6 .5mm cancellous screws. Clin Orthop, 1991, 267:85
  • 10[2]Pantazopoulos T, Mousafiris C. Surgical treatment of central acetabular fractures. Clin Orthop, 1989,246:57

共引文献23

同被引文献133

引证文献10

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部