血清中丙肝病毒的压电免疫传感器检测

Detection of Piezoelectric Immunosensor in the Blood Sample for Hepatitis C
下载PDF
导出
摘要 构建一种新型的丙肝压电免疫传感器。采用AT切型、基频为10MHz石英晶体作为换能器,在清洗后的晶体金电极表面固定蛋白A之后固定丙肝的单克隆抗体,最后检测血清样品中的丙肝病毒。研究了不同固定方法的固定效果,并采用最佳方法做了阴阳对照实验、清洗实验、封阻实验、温度实验等,得到了初步的结果。此传感器具有特异性好、不需标记、操作简单、能实时在线检测和重复使用等优点,在临床实验诊断应用中具有潜在前途。 A new piezoelectric immunosensor that can detect hepatitis C is designed. Firsdy we utilize an AT-cut 10MHz quartz crystal as the transducer, immobilize Protein on the polished golden electrode. Then immobilize monoclonal antibody of hepatitis C, and finally detect hepatitis C vires in the blood samples. Experimentally, we analyze the results of several immobilized ways and adopt the best way to accomplish experiments, such as on negative and positive blood samples, rinse effect, blocking, temperature, and etc. These parameters are elementarily accepted in the clinical application. The experimental result shows the sensor has many merits such as well specificity, free label, simple operation, real-time detection, repeated used. So it is useful in clinical laberatory and has merits in clinical application.
出处 《北京生物医学工程》 2005年第6期432-435,共4页 Beijing Biomedical Engineering
基金 广东省重点攻关项目(2KM04301S) 全军医卫科研基金项目(98M038)资助
关键词 血样 丙肝病毒 免疫传感器 检测 blood sample hepatitis C virus immunosensor detect
  • 相关文献

参考文献5

  • 1Florence Komurian-Pradel, Glaucia Paranhos-Baccala, Mireille Sodoyer, et al. Quantitation of HCV RNA using real-time PCR and flurimetry [J]. Journal of virological methods, 2001, 95:111 -119.
  • 2SU XL, LI YB. A self-assembled monolayer-based piezoelectric immunosensor for rapid detection of Escherichia coli O157: H7[J]. Biosensors and Bioelectronics, 2004, 19:563-574.
  • 3张波,府伟灵,毛琼国,陈庆海,张雪,陈鸣,俞凡.压电免疫传感器两种抗体固定方法的比较研究[J].中华医院感染学杂志,2004,14(1):11-14. 被引量:8
  • 4Kurtz J B, Boxall E, Qusir N, et al. The diagnostic significance of an assay for total' hepatitis C core antigen [J]. Journal of virological methods, 2001, 96:127 - 132.
  • 5Paul Ingravallo, Frederick Lahser, Ellen Xia, et al.Characterization of monoclonal antibodies that specifically recognize the palm subdomain of hepatitis C virus nonstructural protein 5B polymerize [J]. Virus research, 2001, 75: 179- 187.

二级参考文献9

  • 1[2]Xing WL, Ma LR, Jiang ZH, et al. Portable fiber-optic immunosensor for detection of methsulfuron methyl[J]. Talanta, 2000, 52(5): 879-883.
  • 2[3]Naimushin AN, Soelberg SD, Nguyen DK, et al. Detection of Staphylococcus aureus enterotoxin B at femtomolar levels with a miniature integrated two-channel surface plasmon resonance (SPR) sensor[J]. Biosensors Bioelectron, 2002, 17(6-7): 573-584.
  • 3[4]Wong YY, Ng SP, Ng MH, et al. Immunosensor for the differentiation and detection of Salmonella species based on a quartz crystal microbalance[J]. Biosensors Bioelectron, 2002, 17(8): 676-684.
  • 4[5]Chaki NK, Vijayamohanan K. Self-assembled monolayers as a tunable platform for biosensor applications[J]. Biosensors Bioelectron, 2002, 17(1-2): 1-12.
  • 5[8]Sergeyeva TA, Lavrik NV, Rachkov AE, et al. An approach to conductometric immunosensor based on phthalocyanine thin film[J]. Biosensors Bioelectron, 1998, 13(3-4): 359-364.
  • 6[9]Wang C, He XW, Chen LX. A piezoelectric quartz crystal sensor array self assembled calixarene bilayers for detection of volatile organic amine in gas[J]. Talanta, 2002, 57(6): 1181-1188.
  • 7裴仁军,胡继明,胡毅,曾云鹗.蛋白A定向固定抗体的纤维蛋白压电免疫传感器的研究[J].高等学校化学学报,1998,19(3):363-367. 被引量:26
  • 8张波,府伟灵,蒋天伦,陈鸣,俞凡,陈小兵.压电石英晶体微阵列免疫传感器检测hCG的实验研究[J].第三军医大学学报,2002,24(1):35-38. 被引量:13
  • 9陈鸣,府伟灵,蔡国儒,刘明华,张波,蒋天伦,陈庆海,秦廷辉.肽核酸生物传感器直接检测临床标本中提取的病毒基因组DNA[J].中华医院感染学杂志,2003,13(7):616-619. 被引量:13

共引文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部