期刊文献+

微柱凝胶技术在红细胞不规则抗体筛选中的应用 被引量:21

Application of Microtubes Gel Test in Irregulate Antibodies Screening
下载PDF
导出
摘要 目的观察微柱凝胶法和凝聚胺法的抗体检出率,探讨微柱凝胶法的临床应用价值。方法应用微柱凝胶技术对6 056例术前备血患者血清进行抗体筛选和鉴定,同时与凝聚胺法比较。结果微柱凝胶法抗体筛选阳性20例,凝聚胺法抗体筛选阳性17例。结论微柱凝胶法优于凝聚胺法,可以用于临床常规检测。 Objective To investigate the positive rate for irregulate erythrocyte antibodies by mlcrotubes gel test(MGT) and moditying polybrene test (MPT),explore the value of MGT in clinic. Methods 6056 samples of blood recipients were screened and identified for irregulate erythrocyte antibodies by MGT,and compared with MPT. Results The irregulate erythrocyte antibodies were detected in 20 cases by MGT,while they were detected in 17 cases by MPT. Conclasion MGT is superior to MPT,and it can be used for normal test in clinic.
出处 《现代检验医学杂志》 CAS 2006年第1期37-38,共2页 Journal of Modern Laboratory Medicine
关键词 微柱凝胶法 凝聚胺法 不规则抗体筛选 microtubes gel test moditying polybrene test irregulate antibodies screening
  • 相关文献

参考文献5

  • 1陈忠,王雪明.手工凝聚胺技术的应用[J].临床检验杂志,1997,15(1):61-62. 被引量:21
  • 2Care JC,Reilly N. Evaluation and implementation of the gel test for indirect antlglobulintestlng in a community hospital laboratory [J]. Arch Pathol Lab Med, 1999,123(8):693.
  • 3Langston MM,Procter JL, Cipolone KM, et al. Evaluation of the gelsystem for ABO grouping and D typing[J]. Transfusion, 1999,39(3): 300.
  • 4肖露露 戴丽蓉 袁星芯.Rh血型系统抗—C引起配血不合1例[J].中国输血杂志,1997,10(1):33-33.
  • 5万汝根.抗—C、抗—e引起配血不合1例[J].中国输血杂志,1999,12(1):27-27.

二级参考文献4

  • 1陈忠.红细胞血型抗体测定与抗体鉴定[J].临床检验杂志,1994,12(1):49-52. 被引量:4
  • 2团体著者,输血技术手册,1985年,536页
  • 3颜学军,国外医学输血及血液学分册,1983年,6卷,1期,8页
  • 4林玛利,中国输血杂志,1995年,8卷,2期,105页

共引文献22

同被引文献115

引证文献21

二级引证文献132

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部