期刊文献+

^(60)Co和^(137)Csγ射线参考辐射场及测定其空气比释动能(率)的系 被引量:7

 ̄(60)Co AND  ̄(137)Cs GAMMA RAY REFERENCE RADIATION FIELD AND THE STANDARD CAVITY IONIZATION CHAMBERS USED FOR AIR KERMA DETERMINATION
下载PDF
导出
摘要 本实验室建立了60Co和137CSγ射线参考辐射场,并研制了不同体积的系列球形石墨空腔电离室,用于测定辐射场的空气比释动能率。对于30cm3和50cm3电离室,估计总不确定度为0.74%,与国内照射量标准符合得相当好,与日本国家标准(ETL)比对结果也在1%内相符。用这些电离室对本实验室所建立的60CO和137CSγ射线参考辐射场空气比释动能率(或照射量率)进行测定,与1990年MCD-100电离室测量结果都在2%内相符。 Co and 137Cs gamma ray reference radiation field has been established and a series of spherial graphite cavity chambers of different volume for 60Co and 137Cs gamma ray airKerma determination have been developed in this laboratory. For 30 cm3 and 50 cm3 chambers, the total uncertainty is evaluated to be 0. 74%, which is in good agreemeet with thenational exposure standards and within 1% as compard with Japanese National Standard in Electrotechnical Laboratory (ETL) for both 60Co and 137Cs.The reference radiation beams used for radiation protection dosimeters' calibration inthis laboratory are measured with these chambers. The results consist with that of 1991measurement within 2 %.
出处 《辐射防护》 CAS CSCD 北大核心 1996年第2期88-97,共10页 Radiation Protection
关键词 钴60 铯137 空气比释动能 β射线辐射 Cavity Ionization Chamber, Air Kerma, Exposure, Reference Radiation, ̄(60)Co, ̄(137)Cs
  • 引文网络
  • 相关文献

参考文献5

  • 1李景云,毕全理,胡家成.低水平 X、γ剂量仪表校准的实验室标准[J].辐射防护,1989,9(2):127-134. 被引量:4
  • 2团体著者,1990年
  • 3团体著者,1986年
  • 4匿名著者,国际电离辐射咨询委员会第1委员会(CCEMRI.1)第4次会议报告,1985年
  • 5匿名著者,国际电离辐射咨询委员会第1委员会(CCEMRI.1)第8次会议,1985年

二级参考文献2

  • 1李景云,辐射防护,1988年,8卷,410页
  • 2李桂珍,1983年

共引文献3

同被引文献88

引证文献7

二级引证文献13

;