小主动脉瓣环患者应用Regent机械瓣术后心功能变化的评价 被引量:6

Evaluation of the heart function of replace st.jude medical regent valae in patients with small aortic
下载PDF
导出
摘要 目的探讨小主动脉瓣环(直径≤19mm)患者行St.Jude Medical Regent(SJM Regent)瓣膜置换术后的心功能改变,研究是否存在植入瓣膜与患者不匹配(Prosthesis-Patient Mismatch,PPM)现象.以及是否有行主动脉瓣瓣环扩大术的必要。方法2004年3月-2005年3月,22例主动脉瓣环直径≤19mm患者置换SJM Regent机械瓣,用彩色多普勒超声仪对左心功能进行术前、术后监测.并与22例置换St.Jude Medical Hemodynamic Plus Series(SJMHP)机械瓣及22例置换外径23mm常规机械瓣患者进行对比。结果置换SJM Regent机械瓣膜患者术后的左心功能指标较术前明显好转,左室射血分数、左室缩短分数、瓣膜有效开口面积/体表面积之比(EOA指数)明显上升,左室重量指数及主动脉跨瓣压差也有不同程度降低。左心功能各项指标改善明显好于置换SJMHP机械瓣患者.部分指标接近或好于置换外径23mm瓣膜者。结论对于小主动脉瓣环患者.置换Regent机械瓣后指标已经接近或达到置换外径23mm常规瓣膜者,无PPM现象,大部分患者无须行主动脉瓣瓣环扩大术。 Purpose To evaluate the change of left heart function in patients who replace st. jude medical regent valve of small aortic. Methods Twenty-two patients receiving small st. jude medical regent valve prosthesis(≤19 mm in diameter)were studied by Doppler echocardiography(groupⅠ). Before the operation and 1 year after operation, the results were compared with those of 22 patients receiving st. jude medical hemodynamic plus series(groupⅡ) and bigger valve prosthesis(23 mm in diameter)(groupⅢ). Results There was a significant increase in the left ventricular ejection fraction, fractional shortening, the indexed effective orifice area in all groups. There was a significant reduction in the left ventricular mass index,peak pressure gradients across aortic valve in all groups. But left heart function of the patients in groupⅠ was improved better than groupⅡ. Conclusions Patients receiving small st. Jude Medical Regent valve prosthesis have no prosthesis-patient mismatch. Left heart function of replace St. Jude Medical Regent valve is better than replace st. jude medical henlodynamic plus series valve.
出处 《复旦学报(医学版)》 CAS CSCD 北大核心 2006年第2期251-253,共3页 Fudan University Journal of Medical Sciences
关键词 小主动脉瓣环 SJM Regent机械瓣 HP机械瓣 左心功能 植入瓣膜与患者不匹配 small aortic root heart valve prosthesis st. jude medical regent valve st.jude medical hemodynamic plus series left ventricular function prosthesis-patient mismatch
  • 相关文献

参考文献8

  • 1Tasca G,Brunelli F,Cirillo M,et al.Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement[J].Ann Thorac Surg, 2005,79(2):505
  • 2Rahimtoola SH.The problem of valve prosthesis-patient mismatch[J].Circulation, 1978,58(1):20
  • 3Takai H,Yamachika S,Hazama S,et al.Consideration of prosthesis-patient mismatch and left ventricular mass regression after implantation of the Carpentier-Edwards pericardial valve in elderly Japanese patients: body surface area may be irrelevant[J].J Artif Organs, 2004,7(4):203
  • 4Pibarot P,Dumesnil JG.Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention[J].J Am Coll Cardiol,2000(36):1131
  • 5Okumiya, Toshika IN, Mitsuko D,et al.Evaluation of intravascular hemolysis with erythrocyte creatine in patients with cardiac valve prostheses[J].Chest, 2004,(1):13
  • 6Blais C,Dumesnil JG,Baillot R,et al.Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement[J].Circulation, 2003,26;108(8):983
  • 7赵东,王敏生,王春生,洪涛.超声心动图评价小主动脉瓣环者机械瓣置换术后的心功能改变[J].中华胸心血管外科杂志,2001,17(4):216-218. 被引量:7
  • 8Bach DS,Goldbach M,Sakwa MP,et al.Hemodynamics and early performance of the St.Jude Medical Regent aortic valve prosthesis[J].J Heart Disease, 2001(10):436

二级参考文献2

  • 1Rao V,J Thorac Cardiovasc Surg,1999年,117卷,431页
  • 2Sawant D,Ann Thorac Surg,1997年,63卷,964页

共引文献6

同被引文献43

  • 1王红兵,周更须,郑奇军,陈文生,蔡振杰,刘维永.小主动脉瓣环患者主动脉瓣置换术41例[J].中国胸心血管外科临床杂志,2006,13(1):52-53. 被引量:8
  • 2褚衍林,李鲁,吴英渝,唐明达,张坚,顾洪斌.风湿性心脏瓣膜替换术后远期疗效观察[J].中国循环杂志,2006,21(2):140-142. 被引量:3
  • 3苗齐,刘兴荣,马国涛,张超纪,曹丽华.St.Jude Medical Regent主动脉瓣应用于小主动脉瓣环患者的初步经验[J].中国心血管病研究,2006,4(6):404-406. 被引量:2
  • 4程力剑,张尔永,郭应强.19mm St.Jude Regent瓣有效瓣口面积和血流动力学的早期在体研究[J].中国胸心血管外科临床杂志,2007,14(4):256-260. 被引量:8
  • 5Kunihara T,Schmidt K,Glombitza P,et al.Root replacement using stentless valves in the small aortic root:a propensity score analysis[J].Ann Thorac Surg,2006,82(4):1379-1384.
  • 6Pibarot P,Dumesnil JG.Prosthesis-patient mismatch:definition,clinical impact and prevention[J].Heart,2006,92(8):1022-1029.
  • 7Koch CG,Khandwala F,Estafanous FG,et al.Impact of prosthesis patient size on functional recovery after aortic valve replacement[J].Circulation,2005,111(24):3221-3229.
  • 8Borger MA,Prasongsukarn K,Armstrong S,et al.Stentless aortic valve reoperations:a surgical challenge[J].Ann Thorac Surg,2007,84(3):737-743.
  • 9Freed DH,Tam JW,Moon MC,et al.Nineteen-millimeter prostheticaortic valves allow normalization of left ventricular mass in elderly women[J].Ann Thorac Surg,2002,74(6):2022-2025.
  • 10Kunihara T,Schmidt K,Glombitza P,et al. Root replacement using stentless valves in the small aortic root: a propensity score analysis. Ann Thorac Surg, 2006,82(4 ) : 1379-1384.

引证文献6

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部