摘要
采用ICP-AES(电感耦合等离子体发射光谱)法,以硝酸镍作为基体改进剂,对淀粉中的铅、砷含量进行了测定;探讨了样品灰化方法及灰化原子化温度、基体改进剂对测定结果的影响。实验结果表明,用ICP-AES方法测定淀粉样品中铅、砷一类有害重金属含量,数据、结果的重现性好,方法简便易行、测定结果准确。
Lead and arsenic contents in amylum were determined by ICP-AES (inductively coupled plasma atomic emission spectroscopy) method with the addition of Ni(NQ3 )2 as the matrix modifier. Detailed discussion was conducted about the impact of factors such as ashing and automation temperature, ashing method of samples, and matrix modifier on the experimental results. The experimental results showed that ICP-AES method is easy, rapid and exact, its return character is good, and it can be used in the inspection of heavy metals such as lead and arsenic in amylurn.
出处
《光谱学与光谱分析》
SCIE
EI
CAS
CSCD
北大核心
2006年第3期554-556,共3页
Spectroscopy and Spectral Analysis