期刊文献+

有限内固定结合微型外固定架治疗手部骨折 被引量:33

Limited internal fixation combined with external fixator for intra-articular or periarticular fractures of the hand
原文传递
导出
摘要 目的总结应用有限内固定结合微型外固定架治疗手部关节内或关节周围骨折的方法及疗效。方法2002年5月-2005年2月,对15例手部关节内或关节周围骨折的患者,应用有限内固定结合Orthofix微型外固定装置进行治疗。结果术后骨折全部愈合,愈合时间为6~12周,平均8周。按TAM标准评定手指活动度其优良率达93.3%。术后无钢针断裂、松动及针道感染等并发症。结论有限内固定结合微型外固定架治疗手部关节内或关节周围骨折具有微创、固定可靠、疗效肯定等优点,为手部关节内或关节周围骨折的治疗提供了一种新的思路。 Objective To report the methods and results of using limited internal fixation combined with mini external fixator for treatment of intra-articular or pefiarticular fractures of the hand. Methods Fifteen cases intra- articular or pefiarticular fractures of the hand were treated with limited internal fixation combined with Orthofix minifixator from May 2002 to February 2005. All cases were follow to observe the fracture union time and joint function postoperatively. Results All cases healed successfully and the average union time was 8 weeks with a range of 6 to 12 weeks. According to TAM standard, the overall good-excellent rate of joint function was 93.3%. There was no complication such as infection, pin loosening, pin breakage, etc. Conclusion Limited internal fixation combined with mini external fixator is a minimally invasive, reliable and effective treatment option for intra-articular or periarticular fractures of the hand.
出处 《中华手外科杂志》 CSCD 北大核心 2006年第4期219-220,共2页 Chinese Journal of Hand Surgery
关键词 骨折 手损伤 骨折固定术 外固定器 Fractures Hand injuries Fracture fixation, internal External fixators
  • 引文网络
  • 相关文献

参考文献8

二级参考文献23

  • 1Muller ME 荣国威(译).骨折内固定学,第1版[M].北京:人民出版社,1995.1-48.
  • 2张建新 胥少汀 等.微型钢板固定治疗掌骨骨折[J].中华手外科杂志,1994,10:254-254.
  • 3Krettek C, Schandelmaier P, Tscherne H.Nonreamed interlocking nailing of closed tibial fractures with severe soft tissue injury.Clin Orthop, 1995, (315): 34-47.
  • 4Gregory P, Sanders R. The treatment of closed, unstable tibial shaft fractures with unreamed interlocking nails. Clin Orthop,1995, (315): 48 -55.
  • 5Blachut PA, Meek RN, O'Brien PJ. External fixation and delayed intramedullary nailing of open fractures of the tibial shaft: a sequential protocol. J Bone Joint Surg(Am), 1990,72:729 -735.
  • 6Mayr E, Braun W, Ruter A. Can unreamed tibial nailing replace external fixators in management of open tibial fractures?Chirurg, 1994, 65: 983-987.
  • 7Palmer RH. Biological osteosynthesis. Vet Clin North Am Small Anim Pract, 1999, 29:1171 - 1185.
  • 8Weller S. Hontzsch D. Frigg R.Epiperiostal, percutaneous plate osteosvnthesis: a new minimally invasive technique with reference to "biological osteosynthesis".Unfallchirurg. 1998.101: 115-121.
  • 9Farouk O, Krettek C. Miclau T. et al.Minimally invasive plate osteosvnthesis: dose percutaneous plating disrupt femoral blood supply less than the traditional technique? J OrthopTruama. 1999. 13:401-406.
  • 10Ruedi TP, Sommer C, Leutenegger A. New techniques in indirect reduction of long bone fractures. ClinOrthop, 1998, (347): 27-34.