摘要
通过详细的计算数据对几种不同类型的壳管式换热器在不同条件下部分负荷时的性能做出分析和比较从中得出结论,并从冷水机组的长期运行费用方面对空调系统的设计提出建议。
The study is focused on the heat exchanger performance on the part load condition since the chiller is usually operated on the part load condition. The analysis and conclusion that based on a number of calculation data from the reliable models are made between three different types of shell and tube heat exchanger.
出处
《制冷与空调》
2006年第4期86-88,共3页
Refrigeration and Air-Conditioning
关键词
壳管式
换热器
性能
部分负荷
shell and tube
heat exchanger
performance
part load