摘要 蓄电池长期储存一般分湿贮法和干贮法两种。详细介绍了两种方法的适用条件以及具体的实现步骤,对提高仓库的蓄电池管理水平具有很强的指导意义。最后,通过对不同年代生产的干贮蓄电池的初期容量和循环寿命检测,找出了蓄电池性能随储存时间变化的规律并对现象进行了解释,证实了长期干态贮存蓄电池的电性能仍能符合技术要求。 The secondary battery has two kinds of ways for long storage: one is dry storage, and the other is wet storage. The applicable conditions and material processes were described, and which could guide the manager level of the depots. The mutative rules of the battery's performance followed with the storage time were found by the detecting of initial capacity and circular life of dry stored batteries produced in different ages. The phenomenon was explained and the fact that the dry stored batteries could meet technological requirements was proven.
出处 《电源技术》 CAS CSCD 北大核心 2006年第12期991-992,共2页 Chinese Journal of Power Sources
关键词 库存 蓄电池 维护 检测 容量 storage second battery maintenance detect capacity