摘要
研究了工业电网中由中频电源产生谐波的机理,指出中频电源为电流型谐波源,抑制中频电源所引起的谐波应首先抑制谐波电流。分析了中频电源交流侧和电网侧的谐波特性,并针对中频电源的谐波类型提出了几种谐波抑制措施。所得结论对治理中频电源引起的谐波污染具有理论指导意义。
The mechanism of harmonic caused by medium-frequency power supply in the rural power network is analyzed. It indicates that medium-frequency power supply is the source of harmonic current. Firstly, so harmonic current should be suppressed rather than harmonic voltage. The harmonic characteristic on the AC side of medium-frequency power supply and the network side is analyzed. The measures of the harmonic suppression of medium-frequency power supply are put forward. Some results have been indicated significance of theories to control the harmonic pollution caused by medium-frequency power supply.
出处
《煤矿现代化》
2007年第2期43-45,共3页
Coal Mine Modernization
关键词
中频电源
谐波源
谐波抑制
工业电网
medium-frequeney power supply, harmonic source, harmonic suooression, industrial Dower network.