期刊文献+

正常人、高眼压症及青光眼患者的中央角膜厚度 被引量:4

下载PDF
导出
摘要 目的:探讨正常人、高眼压症及青光眼患者中央角膜厚度(CCT)的差异。方法:应用超声测厚仪测量正常人(26例)、高眼压症(OHT,28例)、慢性闭角型青光眼(CACG,13例)、原发性开角型青光眼(POAG,24例)患者的中央角膜厚度并比较四组入选者之间是否存在差异。结果:所有被测者的平均CCT为558μm±40μm。正常人(536±37)μm、CACG(553±38)μm、POAG(545±31)μm三组的平均CCT无显著性差异(P≥0.573)。OHT的平均CCT(591±29)μm显著厚于其它三组(P≤0.001)。结论:CACG、POAG与正常人的平均CCT无显著性差异。OHT患者的平均CCT较其它三组的厚。
出处 《工企医刊》 2007年第2期29-30,共2页 The Medical Journal of Industrial Enterprise
  • 相关文献

参考文献4

  • 1Goldmann H,Schmidt T.Uber applanationstonometrie.Ophthalmologica.1957;134:221~242.
  • 2Ehlers N,Bramsen T,Sperling S.Appolanation tonometry and central corneal thickness.Acta Ophthalmol(Copenh).1975;53:34~43.
  • 3方敏,余敏斌.高眼压症认识新进展[J].国外医学(眼科学分册),2004,28(5):312-316. 被引量:22
  • 4Gordon MO,Beiser JA,Brandt JD,et al.The Ocular Hypertension Treatment Study:baseline factors that predict the onset of primary open-angle glaucoma.Arch Ophthalmol.2002;120:714~720.

二级参考文献24

  • 1Stodtmeister R. Applanation tonometry and correction according to corneal thickness. Acta Ophthalmol Scand, 1998, 76:319-324.
  • 2Argus WA. Ocular hypertension and central corneal thickness.Ophthalmology, 1995, 102: 1810-1812.
  • 3Medeiros FA,Sample PA, Weinreb RN. Corneal thickness measurements and visual function abnormalities in ocular hypertensive patients. Am J Ophthalmol, 2003,135: 131-137.
  • 4Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol, 2000,44:367-408.
  • 5Damji KF, Muni RH, Munger RM. Influence of corneal variables on accuracy of intraocular pressure measurement. J Glaucoma,2003, 12: 69-80.
  • 6Foster PJ, Baasanhu J, Alsbirk PH, et al. Central corneal thickness and intraocular pressure in a Mongolian population. Ophthalmology, 1998,105: 969-973.
  • 7Gordon MO, Beiser JA, Brandt JD, et al. The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol, 2002, 120: 714-720.
  • 8Wax MB. Emerging perspectives in glaucoma: optimizing 24-hour control of intraocular pressure. Am J Ophthalmol, 2002, 133(Suppl): S1 - 10.
  • 9Asrani S, Zeimer R, Wilensky J, et al. Large diurnal fluctuations in intraocular pressure are an independent risk factor in patients with glaucoma. J Glaucoma, 2000, 9:134-142.
  • 10Newell FW, Krill AE. Diurnal tonography in normal and glaucomatous eyes. Trans Am Ophthalmol Soc, 1964, 62: 349-374.