摘要
The absorption of low concentration SO2 in flue gas by using the module of liquid-containing microporous membrane which is made up of hollow fiber and citric acid-sodium citrate buffer solution was investigated.The absorption efficiency of hydrophilic and hydrophobic membranes by using the concept of dynamic contact angle was mainly studied.The influences on absorption efficiency from absorption time,flowrate of gas phase,SO2 concentration of gas phase,air pressure,citrate concentration,pH value of solution as well as the generation of sulfate radical in absorption solution were examined.The results indicate that the hydrophobic hollow fiber membrane is better than hydrophilic membrane,the absorption efficiency decreases with increasing absorption time,gas phase flowrate,gas phase SO2 concentration and air pressure,the absorption rate and capacity of SO2 can be improved by increasing the citrate concentration,the absorption efficiency can be improved by increasing the pH value of citrate solution,the concentration of SO42-in absorption solution increases linearly with the absorption time at a rate around 0.192 g/(L-h).
The absorption of low concentration SO2 in flue gas by using the module of liquid-containing microporous membrane which is made up of hollow fiber and citric acid-sodium citrate buffer solution was investigated. The absorption efficiency of hydrophilic and hydrophobic membranes by using the concept of dynamic contact angle was mainly studied. The influences on absorption efficiency from absorption time, flowrate of gas phase, SO2 concentration of gas phase, air pressure, citrate concentration, pH value of solution as well as the generation of sulfate radical in absorption solution were examined. The results indicate that the hydrophobic hollow fiber membrane is better than hydrophilic membrane, the absorption efficiency decreases with increasing absorption time, gas phase flowrate, gas phase SO2 concentration and air pressure, the absorption rate and capacity of SO2 can be improved by increasing the citrate concentration, the absorption efficiency can be improved by increasing the pH value of citrate solution, the concentration of SO42- in absorption solution increases linearly with the absorption time at a rate around 0.192 g/(L.h).
出处
《过程工程学报》
EI
CAS
CSCD
北大核心
2007年第3期483-489,共7页
The Chinese Journal of Process Engineering
基金
Supported by Natural Science Foundation of China (No.50244012)
National Science Foundation of Shaanxi Education Department (No.02JC37)
关键词
微孔膜
柠檬酸
中空纤维
二氧化硫
吸收
动力接触角
hollow fiber
liquid-containing membrane
citric acid
low concentration SO2 absorption
dynamical contact angle