期刊文献+

非球面零位补偿检测中非线性误差的影响及去除 被引量:2

Effect and Removal of Nonlinear Error in Aspheric Mirror Null Testing
下载PDF
导出
摘要 非球面零位补偿检测中会引入非线性误差,利用光线追迹的方法获得了干涉测量坐标系和非球面镜面坐标系之间的非线性关系。对某有效通光口径为860mm的体育场形离轴非球面反射镜的零位补偿检测,利用光线追迹结果进行坐标反变换的数据处理方法,对上述非球镜面面形数据进行了镜面矢高分布数据的非线性校正;通过分析对比非线性校正前后的数据,对计算机辅助装调过程的影响,证明经过非线性校正后的镜面面形矢高数据可以加速计算机辅助装调过程收敛。 Null testing of aspheric mirrors induces nonlinear errors, the nonlinear relation between interferometry coordinate and aspheric mirror coordinate have been obtained by ray tracing. Through analyzing the null testing process of one stadium-shaped off-axis aspheric mirror with an effective clear aperture of 860 mm, the surface shape data of the aspheric mirror provided by the null testing had been corrected by the coordinate inverse transforming method with the ray tracing result. Through the contrast analysis of the effect in computer-aided alignment between corrected and uncorrected surface data, it can be concluded that after nonlinear corrections, the surface shape data of aspheric mirrors can meet the requirement of computer-aided alignment.
出处 《科学技术与工程》 2007年第16期4150-4152,4162,共4页 Science Technology and Engineering
关键词 离轴非球面 零位补偿检测 干涉测量 非线性校正 计算机辅助装调 off-axis aspheric mirror null testing interferometry nonlinear correcting computeraided alignment
  • 相关文献

参考文献2

二级参考文献1

  • 1辛企明,近代光学制造技术,1997年

共引文献16

同被引文献34

  • 1薛栋林,郑立功,王淑平,张学军.离轴二次非球面补偿检验计算机辅助调整技术研究[J].光学精密工程,2006,14(3):380-385. 被引量:10
  • 2Wang D, Yang Y,Ohen C,et al. Polarization point-diffrac- tion interferometer for high-precision testing of spherical surface[A]. Proc. of SPIE[C]. 2010.7656 : 7656.
  • 3Matsuura T. Udaka K. Oshikane Y. et al. Spherical con- cave mirror measurement by phase-shifting point diffrac- tion interferometer with two optical fibers[ J]. Nuclear In- struments & Methods in Physics Research Section A. 2010.616(2-3) :233-236.
  • 4Wang D, Yang Y,Chen C, et al. Point diffraction interfer- ometer with adjustable fringe contrast for testing spherical surfaces[J]. Appl. Opt., 2011,50(16) :2342-2348.
  • 5Lowman A E,Greivenkamp J E. Interferometer errors due to the presence of fringes[J]. Appl. Opt., 1996,35 (34) : 6826-6828.
  • 6Rimmer M P,King C M,Fox D G. Computer program for the analysis of interferometric test data[J]. Appl. Opt., 1972,11(12) :2790-2796.
  • 7ZHOU Ping,Burge J H. Limits for interferometer calibra- tion using the random ball test[A]. Proc. of SPIE[C]. 2009,7426 : 74260U1-12.
  • 8Murphy P E, Brown T G, Moore D T. Measurement and calibration of interferometric imaging aberrations[J]. Ap- pl. Opt. ,2000,39(34) :6421-6429.
  • 9Reichelt S, Pruss C,Tiziani H J. Absolute interferometric test of aspheres by use of twin computer-generated holo- grams[J]. AppI. Opt. ,2003,42(22) :4468-4479.
  • 10WANGDong-sheng,WANG Kai-wei, SHEN Yi-bing, et al. Error analysis of spherical ultra-precision measurement [A]. Proc. of SPIE[C]. 2010,7656,765600.