闭式冷却塔的结构优化 被引量:12

Configuration optimization of closed cooling tower
下载PDF
导出
摘要 以换热面积最小、阻力最小为限制条件,对闭式冷却塔的管式蒸发冷却器的结构优化进行了研究。分析了结构参数对管式蒸发冷却器的面积及风机和水泵能耗的影响。研究结果表明:长度、宽度在合适的范围内取值,盘管为正三角形布置,盘管内径为0.019 m,管间距是盘管内径的2倍,管材选用无缝钢管时,可以使闭式冷却塔的投资费用和运行费用综合达到最小。 With minimal heat exchange area and minimal resistance as restrict condition,the research on configuration optimization of tubular evaporative cooler of closed cooling tower was made.The influence of configuration parameter on the heat exchange area of the tubular evaporaive cooler and the energy consumption of the fans and pumps was analyzed.The findings indicated that: length and width value in appropriate scope,coil tube arranged as equilateral triangle,inside diameter of the coil tube was 0.019 m,the space between the tubes was 2 times the inside diameter of the coil tube,using seamless steel pipe as the tube material could make the investiment cost and the operating cost synthetically achieve minimum.
出处 《工业用水与废水》 CAS 2007年第4期114-117,共4页 Industrial Water & Wastewater
关键词 闭式冷却塔 管式蒸发冷却器 目标函数 影响因素 closed cooling tower tubular evaporative cooler object function influence factors
  • 相关文献

参考文献2

  • 1薛覆中.工程最优化技术[M].天津:天津大学出版社,1998.
  • 2尾花英朗(日).热交换器手册(下册)[M].徐中权译.北京:石油工业出版社,1987.

共引文献2

同被引文献98

引证文献12

二级引证文献65