期刊文献+

上肢动作研究量表在脑卒中患者中的信度 被引量:10

Reliability of the Action Research Arm Test in Stroke Patients
下载PDF
导出
摘要 目的探讨上肢动作研究量表(ARAT)在脑卒中患者中的评价者间信度、评价者内信度和内在一致性。方法由两位评价者各自独立的对30例慢性脑卒中患者进行ARAT的评价。检验ARAT的评价者间信度、评价者内信度和内在一致性。结果ARAT的评价者间信度和评价者内信度ICC值分别为0.992和0.987。内在一致性分析结果Cronbach'sα系数为0.936。结论ARAT在脑卒中患者中具有良好的评价者间信度、评价者内信度和内在一致性。 Objective To verify the inter-rater reliability,intra-rater reliability and internal reliability of the action research arm test(ARAT)in patients with chronic stroke.Methods 30 people with chronic stroke were tested with the ARAT by two experienced raters.The inter-rater reliability,intra-rater reliability and internal reliability were examined.Results The ARAT showed high inter-rater reliability and intra-rater reliability(ICC=0.992 and 0.987,respectively)and internal consistency(Cronbach's alpha coefficient=0.936).Conclusion The ARAT shows good inter-rater reliability,intra-rater reliability and internal reliability in assessing patients after stroke.
出处 《中国康复理论与实践》 CSCD 2007年第9期868-869,共2页 Chinese Journal of Rehabilitation Theory and Practice
基金 解放军总医院科研基金(06MP78)
关键词 上肢动作研究量表 脑卒中 信度 action research arm test(ARAT) stroke reliability
  • 相关文献

参考文献7

  • 1Croarkin E, Danoff J, Barnes C. Evidence-based rating of upper-extremity motor function tests used for people following a stroke[J]. Physical Therapy, 2004, 84(1):507-512.
  • 2Lang CE, Wagner JM, Dromerick AW, et al. Measurement of upper-extremity function early after stroke: properties of the action research arm test[J]. Arch Phys Med Rehabil, 2006, 87(12) : 1605-1610.
  • 3Church C, Price C, Pandyan AD, et al. Randomized controlled trial to evaluate the effect of surface neuromuscular electrical stimulation to the shoulder after acute stroke[J]. Stroke, 2006,37 (12) : 2995 -3001.
  • 4Platz T, Eickhof C, van Kaick S, et al. Impairment-oriented training or Bobath therapy for severe arm paresis after stroke: a singleblind, multicentre randomized controlled trial [J]. Clin Rehabil, 2005,19(7) : 714-724.
  • 5Hsieh CL, Hsueh IP, Chiang FM, et al. Inter-rater reliability and validity of the Action Research Arm Test in stroke patients[J]. Age Ageing,1998,27(2):107-113.
  • 6Platz T, Pinkowski C, van Wijek F, et al. Reliability and validity of arm function assessment with standardized guidelines for the FuglMeyer Test, Action Research Arm Test and Box and Block Test; a multieentre study[J]. Clin Rehabil, 2005, 19(4):404-411.
  • 7Hsueh IP, Hsieh CL. Responsiveness of two upper extremity function instruments for stroke inpatients receiving rehabilitation [J]. Clin Rehabil, 2002, 16(6): 617-624.