摘要
给出了在采用原–对偶内点法进行校正控制计算时值得注意的初值选取、中心参数选取等一些问题,并针对福建省网168节点系统的实际数据进行了仿真计算。结果表明,在考虑了这些要点后所求得的结果可靠,能较好地满足实际工程要求。
The authors propose some noteworthy problems such as the selection of initial value and centering parameters and so on while PDIPM is adopted to carry out the calculation of corrective control; and the simulation of corrective control based on the actual data of Fujian Power Grid with 168 buses is conducted. Simulation results show that when these problems are taken into account, the obtained results are reliable and can meet the practical requirement better.
出处
《电网技术》
EI
CSCD
北大核心
2007年第21期27-31,共5页
Power System Technology