放射治疗中人体剂量质量保证进展

下载PDF
导出
作者 高磊 罗素明
出处 《中国辐射卫生》 北大核心 2008年第1期119-120,共2页 Chinese Journal of Radiological Health
  • 引文网络
  • 相关文献

参考文献11

  • 1IAEA, Report of team of experts. Investigation of an accidental exposure of radiotherapy patients in Panama [ R ]. Vienna, 2001,1 -50.
  • 2李开宝,罗素明.医用电离辐射物理剂量学的进展[J].中华放射医学与防护杂志,1999,19(3):156-159. 被引量:9
  • 3SUMING LUO, WEIGUO ZHU, Development of TLD procedure for in vivo dosimetry for photon beams in radiotherapy [ J ]. QANTRM,2006,97 - 98.
  • 4AAPM . Report No. 87. Dioede in vivo dosimetry for patients receiving external beam radiation therapy. Report of task group 62 of radiation therapy committee[ R]. Medical Physics Publishing,2005,1 - 12.
  • 5JAN V D GINETTE M. Methods for in vivo dosimetry in external radiotherapy [ J ]. Physics for clinical radiotherapy, 1994,1 - 60.
  • 6祁振宇,邓小武,黄劭敏,康德华,Anatoly Rosenfeld.新型金属氧化物半导体场效应晶体管探测器在放疗剂量监控中的应用[J].中华放射肿瘤学杂志,2006,15(4):329-334. 被引量:8
  • 7皇甫丽英,金平,勾秋静,李冬梅.MOS场效应晶体管辐照特性的实验研究[J].实验技术与管理,2006,23(3):38-40. 被引量:2
  • 8PER H.H. Dosimetric evaluation of a new design MOSFET in vivo dosimeter[ J ]. Med Phys 2005,1 : 110 - 117.
  • 9MAYLES W P M , HEISIG S , MAYLES H M O.. Treatment verification and in vivo dosimetry. Radiotherapy [ J ]. physics, 228 - 232.
  • 10MARIANNE C A. Real - time in vivo luminescence dosimetry in radiotherapy and mammography using A1203 : C [ Z]. Ris National laboratory,2005,17 - 32.

二级参考文献20

  • 1朱小锋,周开明,徐曦.剂量率对MOS器件总剂量辐射性能的影响[J].核电子学与探测技术,2005,25(3):322-325. 被引量:10
  • 2Dong L,Med Phys,1997年,24卷,263页
  • 3李开宝,中华放射医学与防护杂志,1997年,17卷,352页
  • 4尉可道,中华放射医学与防护杂志,1997年,17卷,347页
  • 5Physical aspect of quality assurance in radiation therapy.Radiation Therapy Committee Task Group No.24.In:American Association of Physicists in Medicine,eds.AAPM Report No.13.New York:The American Institute of Physics Inc,1984.23-29.
  • 6Kron T.Chapter 3:dosimetry of therapeutic X-rays.In:Metcalfe P,Kron T,eds.The physics of radiotherapy X-rays.Oxford:Oxford University Press,2000.158-159.
  • 7Soubra M,Cygler J,Mackay G.Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter.Med Phys,1994,21:567-572.
  • 8Absorbed dose determination in photon and electron beams:an international code of practice.In:International Atomic Energy Agency,eds.IAEA Report No.277.Vienna:International Atomic Energy Agency,1987.42-59.
  • 9The use of plane parallel ionization chamber in high energy electron and photon beams:an international code of practice.In:International Atomic Energy Agency,eds.IAEA Report No.381.Vienna:International Atomic Energy Agency,1997.38-47.
  • 10Kron T,Duggan L,Smith T,et al.Dose response of various radiation detectors to synchrotron radiation.Phys Med Biol,1998,43:3235-3259.

共引文献16

;
使用帮助 返回顶部