摘要
以巴基斯坦恰希玛核电站一期辐射监测系统近两年测量数据为依据,对该核电站辐射监测仪表的运行工况进行分析。结果表明:绝大部分辐射监测仪表处于正常运行状态,部分仪表偶尔会出现异常数据。根据工艺过程特点分析了辐射监测仪表出现异常数据的可能性原因,并对辐射监测系统设计的改进提出了建议,供今后核电站辐射监测系统设计参考。
According to the radiation monitoring data in adjacent two years' of Chashrna Nuclear Power Plant, the operating condition of radiation monitoring instrument is analyzed in the paper. The result shows that the radiation monitoring instruments were majority in the normal operating state and occasion- ally given some abnormity data. The possible reason for the abnormity data is analyzed according to the process characteristic. The suggestion for design improvement of the radiation monitoring system is given in the paper. It is referenced for the radiation monitoring system design in the future.
出处
《核电子学与探测技术》
CAS
CSCD
北大核心
2007年第6期1077-1082,共6页
Nuclear Electronics & Detection Technology
关键词
核电站
辐射监测系统
设计改进
建议
nuclear power plant
radiation monitoring system
design improvement
suggestion