摘要
根据液态烃球罐消防降温的要求,结合4 000 m3液态烃球罐消防喷淋的设计计算实例,对球罐的消防喷淋设计方法进行探讨。
Design routines and methods of spraying fire protection system of spherical tank are discussed,according to the fire protection requirements for liquid hydrocarbon spherical tank as well as referring to a design and calculation example for a 4 000 m3 liquid hydrocarbon spherical tank.
出处
《石油化工设备》
CAS
2008年第4期27-30,共4页
Petro-Chemical Equipment
关键词
球罐
液态烃
消防
降温
计算
spherical tank
liquid hydrocarbon
fire protection
temperature drop
calculation