摘要
提出了600MW运行机组双背压凝汽器背压应达值的确定方法,并给出了计算模型。结合定洲发电公司600MW汽轮机组优化试验数据,计算得出了双背压凝汽器的最佳背压和循环水泵最佳运行方式。该方法可用于指导现场节能工作。
The method of defining the pressure value that 600MW unit double pressure condenser' double should attain has been put forward and the computing model has been given. The optimal double pressue of double pressure condenser and the best operating mode of CWR ( circulaing water pump ) have been made with the optimizational experimental data of 600MW unit in Dingzhou Power Plant as an example. The result can be used to guide the save energy at field.
出处
《汽轮机技术》
北大核心
2008年第6期434-436,427,共4页
Turbine Technology
关键词
凝汽器
双背压
计算模型
condenser
double pressure
computing model