期刊文献+

两种调拌方法对藻酸盐印模材尺寸稳定性的影响 被引量:4

The effect of spatulation on the dimension stability of alginate impression
下载PDF
导出
摘要 目的:比较2种调拌方式(人工,机调)下,2种藻酸盐印模材(金玛克专用,普通藻酸钾)精度的变化。方法:按调拌方式和印模材种类分4组:A组为自动调拌机调拌金玛克印模材;B组为自动调拌机调拌藻酸钾印模材;C组为人工调拌金玛克印模材:D组为人工调拌藻酸钾印模材。采用特制的金属模具取模后灌注石膏模型,再测量模型尺寸变化差值,所得数据进行统计分析。结果:采用机调的2种印模材精度均好于人工调拌组;而金玛克专用印模材在机调组中的精度好于普通藻酸钾印模材;人工调拌下金玛克印模材与普通藻酸钾印模材的精度差值差别并不显著。结论:使用自动调拌机调拌的印模材精度优于人工调拌,而以专用的印模材精度最高。 Objective: To compare the effect of two spatulation (artificial control-AC, machine control-MC) on dimension stability of two alginate impression material (Zhermack, alginate kalium). Methods: Four groups of specimens were classified: A: Zhermack spatulated by MC; B: alginate kalium spatulated by MC, C: Zhermack spatulated by AC; D: alginate kalium spatulated by AC. After the impressions of special metal casts were made according to four groups, the dimension value were measured and compared. Results: The dimension stability of Zhermack and alginate kalium spatulated by MC was better than AC; and Zhermack was better than alginate kalium when spatulated by MC, but there was no difference between Zhermack and alginate kalium when spatulated by AC. Conclusion: The dimension stability of alginate impression material spatulated by MC was better than by AC, and Zhermack spatulated with MC could achieve the best stability.
出处 《口腔颌面修复学杂志》 2009年第1期21-23,共3页 Chinese Journal of Prosthodontics
关键词 藻酸盐印模材料 调拌 精度 alginate impression material spatulation accuracy
  • 相关文献

参考文献6

  • 1Ceyhan JA, Johnson GH, Lepe X. The effect of tray selection, viscosityof impression material, and sequence of pour on the accuracy of dies made from dual-arch impression[J]. J rosthet Dent, 2003, 90(2): 143-149.
  • 2Abdullah MA. Surface detail, compressive strength, and dimensional accuracy of gypsum casts after repeated immersion in hypochlorite solution[J]. J Prosthet Dent, 2006, 95 (6): 462-468.
  • 3孙惠强,梁星,包向军,宋宏杰,胡建.自制个别取模器颈缘取模技术精确度的研究[J].口腔颌面修复学杂志,2005,6(2):132-134. 被引量:4
  • 4顾斌,马轩祥,刘杰.超硬石膏材料水粉比对模型精度和表面硬度的影响[J].口腔颌面修复学杂志,2005,6(4):290-292. 被引量:10
  • 5S. Y. Chen, W.M.Liang, F.N. Chen. Factors affecting the accuracy of elastometric impression materials [J]. Journal of Dentistry, 2004, 32(8): 603-609.
  • 6N.Martin. The dimensional stability of dental impression materials following immersion in disinfecting solutions [J]. Dental Materials, 2007, 23 : 760-768.

二级参考文献20

  • 1程静涛,郭天文.托盘间隙对藻酸盐印模材取模精度的影响[J].临床口腔医学杂志,1997,13(2):109-111. 被引量:8
  • 2Mclean J W, von Frauhofer J A .The estimation of cement film thickness by an in vivo technique [J]. Br Dent J, 1971, 131 (3):107~111
  • 3May K B, Russell M M, Razzoog M E, et al. Pre cision of fit:The Procera All ceramic crown[J]. J Prosthet Dent, 1998, 80 (4):394 - 404
  • 4Kohno S, Kanaguchi K, Matsushita K, et al. Utility of the impressiontechniquewiththeindividual tray for cast crown[J].Nippon Hotetsu Shika Gakkai Zasshi, 1989, 33 (3): 558 ~ 570
  • 5MillsteinP, MayaA, Segura C. Determiningtheaccuracy of stock and custom tray impression/casts[J]. J Oral Rehabil, 1998,25(8): 645~648
  • 6Castellani D, Basili M. An alternative method for direct custum tray construction using a visible light-cured resin[J]. J Prosthet Dent, 1997,78 (1):98~ 101
  • 7Dimashkieh MR, Morgano SM. A procedure for making fixed presthodontic impressions with the use of preformed crown shells[J]. J Prosthdt Dent, 1995, 73 (1): 95 ~ 96
  • 8Marshak B, Assif D, Pilo R. A controlled putty-wash impression technique[J]. J Prosthet Dent, 1990, 64 (6):635 ~636
  • 9Chaffee NR,Bailey JH,Sherrard DJ.Dimensional accuracy of improved dental stone and epoxy resin die materials.PartⅠ:Single die[J].J Prosthet Dent,1997,77 (2):131 ~ 135
  • 10Lautenschlager EP,Corbin F.Investigation on the expansion of dental stone[J].J Dent Res,1969,48 (2):206~ 210