广州市公共场所集中空调通风系统微生物卫生状况分析 被引量:14

Microbiological hygiene status of centralized air ventilation system of public places in Guangzhou
原文传递
导出
摘要 目的:调查分析广州市公共场所集中空调通风系统微生物卫生状况,为卫生管理提供依据,预防和控制由空调细菌污染所带来的呼吸道传染病的传播和流行。方法:按照《公共场所集中空调通风系统卫生规范》要求,对5家公共场所集中空调运行期间,采集集中空调送风口空气样品,检测空气中的细菌总数、真菌总数、β-溶血性链球菌。结果:除β-溶血性链球菌外,广州市公共场所集中空调通风系统送风口有细菌总数、真菌总数不同程度的污染。其中细菌总数合格率为71.4%,细菌总数检出范围为27-930 cfu/m^3,最高超标近1倍;真菌总数合格率为85.7%,真菌总数检出范围为7-6000 cfu/m^3,最高超标11倍。结论:公共场所集中空调通风系统应加强微生物卫生管理。 Objective:To investigate sanitary condition of the centralized air ventilation system in public place in Guangzhou to provide the basis for sanitary control. Methods: Air sample was collected in air supplied outlet when centralized air ventilation system was working. The total content of the bacterium and fungus in the air was tested. Results: The centralized air ventilation system was working seriously polluted in which the qualified rate the total content of bacterium was 71.4%. The qualified rate of the total content of fungus was 85.7%. Conclusion: Sanitary control should be strengthened to the centralized air ventilation system.
出处 《中国卫生检验杂志》 CAS 2009年第5期1099-1100,1109,共3页 Chinese Journal of Health Laboratory Technology
基金 广东省卫生厅科技项目(2007-A539)
关键词 公共场所 集中空调通风系统 微生物卫生状况 Public place Centralized air ventilation system Microbiological hygiene status
  • 相关文献

参考文献3

二级参考文献15

  • 1American Society of Heating, Refrigerating and Aironditioning Engineels. Inc. 1999, Ventilation for acceptable indoor air quality. ASHRAE 62- 1999.
  • 2Brown K S. Sick Days at Work[ J]. Environmental Health Perspectives, 1996,104:1032- 1035.
  • 3Burge H A K, Kreiss P R. Morey J, et.al. Guidelines for Assessment and Sampling of Saprophytic Bioaerosols in the Indoor Environment[ J ]. Applied Industrial Hygiene, 1987,2(5) :R10- R16.
  • 4Department of Building Services Engineering Hong Kong Polytechnic University 2000, Good practice guide to indoor air quality for hotels in Hong Kong. Hong Kong Polytechnic University Press.
  • 5Fanger P O, Bluyssen P, Clausen G, et al. Air Pollution Sources in Offices and Assembly Halls[J]. Energy Buildings,1988,12:7 - 19.
  • 6Greene R E, Casey J M, Williams P L.A Proactive Approach for Managing Indoor Air Quality[J]. J Enviromnental Health,1997,60(11) : 15 - 21.
  • 7Hodgson M J, Frohlinger J, Karpf M, et al. Symptoms and Microenvironmental Measures in Nonproblem Buildings[ J]. J Occupational Medicine, 1991,33:527 - 533.
  • 8Indoor Air Quality Management Group of the Government of HKSAR. Guidance notes on managing indoor air quality in air-conditioned buildings and public places. Hong Kong,2000.
  • 9Mikatavage M A, Dillon K,Funkhouser E,et al. Beyond Air Quality- Factors That Affect Prevalence Estimates of Sick Building Syndrome [ J ]. American Industrial Hygiene Association Journal, 1995, 56:1141 - 1146.
  • 10National Air Duct Cleaners Association. Mechanical cleaning of non-porous air conveyance system components. NADCA,1992.

共引文献35

同被引文献140

引证文献14

二级引证文献124

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部