摘要
介绍了用5%FFAP为固定液、在1米不锈钢填充柱中,以萘为内标物,在100℃的柱温下用FID检测器对富马酸二甲酯进行质量分析的方法。该法的变异系数为0.12%,标准偏差为0.12,回收率99.51%,适合于富马酸二甲酯的分析。
In Tc=100℃and using F.I.detector,dimethyl fumarate was analyzed by GC on 5% FFAP packed column using naphthalene as internal standard.The standard deviation was 0.12 and the coefficient of variation was 0.12%.The recovery was 99.51%.It is the proper method for analysis of dimthyl fumarate.
出处
《山东化工》
CAS
1998年第3期46-47,共2页