期刊文献+

分流型芯管对导叶式旋风管内颗粒逃逸的控制 被引量:5

Control of escaped particles by slotted vortex finder in PSC type cyclone tube
下载PDF
导出
摘要 Experimental and computational fluid dynamics was used in this study to predict the escape particles and evaluate the performance of PSC type cyclone tube with slotted vortex finder.The simulation results showed that the PSC type cyclone tube could remove the particles with a diameter greater than 5 μm.The PSC type cyclone tube increased the grade efficiency of particles with a diameter greater than 2 μm as compared with the Shell type cyclone tube.Short circuit flow occurred around the vortex finder slots and there was almost no short circuit flow under the vortex finder inlet.Most small particles escaped from vortex finder slots of the PSC type cyclone tube.The slotted vortex finder could develop "upwards flow" near the vortex finder inlet outside wall and control the escape particles under the vortex finder inlet.The force analysis of particles near the slotted vortex finder slots showed that gas flow carried the particles with a diameter smaller than 3 μm out the separator. Experimental and computational fluid dynamics was used in this study to predict the escape particles and evaluate the performance of PSC type cyclone tube with slotted vortex finder. The simulation results showed that the PSC type cyclone tube could remove the particles with a diameter greater than 5 ~m. The PSC type cyclone tube increased the grade efficiency of particles with a diameter greater than 2 μm as compared with the Shell type cyclone tube. Short circuit flow occurred around the vortex finder slots and there was almost no short circuit flow under the vortex finder inlet. Most small particles escaped from vortex finder slots of the PSC type cyclone tube. The slotted vortex finder could develop "upwards flow" near the vortex finder inlet outside wall and control the escape particles under the vortex finder inlet. The force analysis of particles near the slotted vortex finder slots showed that gas flow carried the particles with a diameter smaller than 3 μm out the separator.
出处 《化工学报》 EI CAS CSCD 北大核心 2010年第1期55-59,共5页 CIESC Journal
基金 教育部重点项目(109159) 中国石油大学研究生创新基金项目
关键词 芯管 逃逸颗粒 短路流 旋风管 slotted vortex finder escaped particles short circuit flow cyclone tube
  • 相关文献

参考文献15

  • 1宋健斐,魏耀东,时铭显.蜗壳式旋风分离器气相流场的非轴对称特性的模拟[J].化工学报,2005,56(8):1397-1402. 被引量:32
  • 2吴小林,熊至宜,姬忠礼,时铭显.旋风分离器旋进涡核的数值模拟[J].化工学报,2007,58(2):383-390. 被引量:60
  • 3胡瓅元,时铭显.蜗壳式旋风分离器全空间三维时均流场的结构[J].化工学报,2003,54(4):549-556. 被引量:61
  • 4Atakan Avci, Irfan Karagoz. Effects of flow and geometrical parameters on collection efficiency in cyclone separators. Aerosol Science, 2003, 34:937- 955.
  • 5Xiang R B, Lee K W. Numerical study of flow field in cyclone of different height. Chemical Engineering and Processing, 2005, 44:877-883.
  • 6Lim K S, Kim H S, Lee K W. Characteristics of the collection efficiency for a cyclone with different vortex finder shapes. Aerosol Science, 2004, 35:743-754.
  • 7Arman Raoufi, Mehrzad Shams, Meisam Farzaneh, Reza Ebrahimi. Numerical simulation and optimization of the fluid flow in cyclone vortex finder. Chemical Engineering and Processing, 2008, 47:128- 137.
  • 8Wang B, Yu A B. Numerical study of the gas- liquid -solid flow in hydrocyclones with different configuration of vortex finder. Chemical Engineering Journal, 2008, 135:33- 42.
  • 9Kim G N, Choi W K, Jung C H. The development and performance evaluation of a cyclone train for removal of contaminated hot particles in a hot cell. Separation and Purification Technology, 2007, 55:313 -320.
  • 10高广德,操波.排气管结构对扩散式旋风分离器性能影响的数值研究[J].机械设计与制造,2008(12):147-149. 被引量:3

二级参考文献48

共引文献163

同被引文献94

引证文献5

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部