摘要
目的:探讨彩色多普勒血流显像(CDFI)诊断下肢深静脉血栓(DVT)的准确性。资料与方法:对44例44条下肢临床疑诊为DVT进行CDFI和上行性静脉造影对比。结果:30条静脉造影确诊为DVT,CDFI诊断准确29条,14条小腿静脉血栓为假阴性。14条下肢静脉造影示正常,CDFI亦未见异常。CDFI诊断DVT的敏感性为96.7%,特异性100%,准确性97.6%。结论:CDFI是无创伤性检查DVT敏感且准确的方法。
Purpose:To assess the accuracy of color Doppler flow imaging(CDFI)in diagnosing deep venous thrombosis(DVT)in lower extremies.Materials and Methods:44 patients clinically suspected of having DVT were comparitively examined using CDFI and ascending phlebography.Results:Phlebography confirmed DVT in 30 patients and negative results in 14.29 patients assessed by CDFI were true positive,14 negative.The sensitivity of CDFI was 96.7%,specificity 100% and accuracy 96.7%.Conclusions:CDFI appeared to be a noninvisive, sensitive and accurate method in detection of DVT of lower extremiies.
出处
《中国医学影像学杂志》
CSCD
1999年第1期45-47,共3页
Chinese Journal of Medical Imaging
关键词
深静脉血栓
下肢
彩超
诊断
deep venous thrombose
color Doppler flow imaging
phlebography