期刊文献+

清洗对热管最大热输出量的影响

Effects of Different Cleaning Processes on Qmax of Heat Pipes
下载PDF
导出
摘要 将铜管毛坯分两组,分别采用常规清洗和超声波清洗后制作成热管。对所有热管进行 Qmax测试和等温性测试,并比较两组的测试结果。结果表明,两组热管的等温性都较为良好,但超声波清洗的热管 Qmax全部合格,而常规清洗的热管 Qmax全部不合格。 Rough copper pipes which are divided into two groups are cleaned with conventional cleaning processes and ultrasonic cleaning processes respectively. And then, rough copper pipes are fabricated into heat pipes. An experimental investigation of the isothermal characteristics and Qmax of heat pipes is conducted. The result shows that the isothermal characteristics of all the heat pipes are fine. But the Qmax of the heat pipes cleaned with ultrasonic cleaning processes are passed while with conventional cleaning processes are not passed.
出处 《制冷与空调(四川)》 2011年第2期179-182,共4页 Refrigeration and Air Conditioning
关键词 热管 最大热输出量 清洗 heat pipes Qmax cleaning processes
  • 相关文献

参考文献3

二级参考文献18

  • 1陈玉成.逆变弧焊整流器的推广应用前景[J].电焊机,1997,27(2):4-6. 被引量:1
  • 2(日)风间茂穗.理想的导热部件--热管的工业应用[M].,..
  • 3(美)G.P.Peterson.热管的制造,试验和应用概况[M].,1994..
  • 4[1]F J Stenger. NASA TM X-1310, 1966
  • 5[2]Maidanik Y F, Vershinin, Kholodov V, J Dolgirev. Heat Transfer Apparatus. U S Patent No.4515209, 1985
  • 6[3]AAVID Engineering Inc.. AAVID Engineering Demos Fluid Cooling System for Notebook Computer. 1993
  • 7[4]Jeffery Kirshberg, Kirk Yerkes, Dave Trebotich, et al. Cooling Effect of a MEMS Based Micro Capillary Pumped Loop for Chip- Level Temperature Control. ASME MEMS-Vol.2, 2000
  • 8MAYDANIK YU F.Loop heat pipes[J].Applied Thermal Engineering,2005,25(5/6):635-657.
  • 9MCGLEN R J,JACHUCK R,LIN S.Integrated thermal management techniques for high power electronic devices[J].Applied Thermal Engineering,2004,24(8/9):1143-1156.
  • 10VASILIEV L L.Heat pipes in modern heat exchangers[J].Applied Thermal Engineering,2005,25(1):1-19.