期刊文献+

基于双曲S变换的变压器励磁涌流和内部故障识别新方法 被引量:14

A new method of identifying inrush and internal faults of power transformer based on H-S transform
下载PDF
导出
摘要 提出了一种基于双曲S变换识别励磁涌流和变压器内部故障的新方法。利用S变换具有优秀时频呈现能力和时频分辨率的特点,采用双曲窗函数,把励磁涌流和故障电流信号变换到相空间进行特征提取,从经过变换以后得到的时频等值线图可以发现二者具有明显不同的特征。通过计算H-S变换后的能量以及1-9层能量与1层能量的比值,发现比值6是区别励磁涌流和故障电流的阈值。仿真分析结果和动模试验均表明:H-S变换可以更清楚地反映信号的时频局部化特性,能准确识别励磁涌流;并且具有较好的抗干扰能力,在变换域易于信号和噪声的分离。 A new method to identify inrush and internal fault of transformer based on hyperbolic S-transform (HST) is discussed. This paper uses the S transform (ST) which has excellent characteristics of time-frequency skills and time-frequency resolution and adopts the Hyperbolic window function. The signals of inrush current and fault current are transformed to phase space by using HST to extract the feature, the time-frequency contours are obtained. It is found that the time-frequency contours in case of inrush are different from that in case of internal faults. By calculating the energy after H-S transform and the ratio of energy level 1-9 and level 1 we found that ratio 6 is the threshold between inrush and fault current. The simulation result and dynamic test show that H-S transform can reflect the signal's time-frequency localization clearly, can identify inrush current, and it has strong capability in noise reduction, and is easy to separate signal from noise in ST domain. This work is supported by Natural Science Foundation of Shaanxi Province (No. 2009JQ7009).
出处 《电力系统保护与控制》 EI CSCD 北大核心 2011年第16期114-120,138,共8页 Power System Protection and Control
基金 陕西省自然科学基金资助项目(2009JQ7009) 陕西省教育厅专项基金资助项目(2010JK750) 西安理工大学科技创新计划
关键词 变压器差动保护 励磁涌流 内部故障 H-S变换 信噪分离 transformer differential protection, inrush current: internal faults H-Stransform: signal-noiseseparation
  • 引文网络
  • 相关文献

参考文献14

  • 1Bogdan Kasztenny, Mladen Kezunovic. Digital relays improve protection of large transformer[J]. IEEE Computer Applications in Power, 1998, 11 (4): 39-45.
  • 2LIU Pei, Malik Op, CHEN De-shu. Improved operation of differential protection of power transformers for internal fault[J]. IEEE Trans on Power Delivery, 1992, 7 (4) : 1246-1251.
  • 3倪良华,姚春球.故障电流与励磁涌流的EMD特性分析[J].电力系统保护与控制,2009,37(10):27-32. 被引量:8
  • 4唐跃中,刘勇,郭勇,刘世明,陈德树.几种变压器励磁涌流判别方法的特点及其内在联系的分析[J].电力系统自动化,1995,19(9):53-59. 被引量:54
  • 5梁志坚,古斌,谭建成,李啸骢.基于非饱和区波形正弦度的涌流识别算法研究[J].电力系统保护与控制,2009,37(9):73-77. 被引量:3
  • 6王世勇,孙鸣,丁中奎.一种基于支持向量机的变压器励磁涌流判别新方法[J].继电器,2008,36(5):1-6. 被引量:8
  • 7Samah E1 Salty, Sammia Gharieb. A wavelet fuzzy expert technique for classification of power transformer transients[C].//2006 International Conference on Power System Technology, 2006: 129-135.
  • 8Strockwell R G, Mansinha, Lowe, R P. Localization of the complex spectrum: the S-Transform [J]. IEEE Trans Signal Process, 1996, 44 (4): 998-1001.
  • 9Liavanos G, Ranganathan N, Jiang J. Heart sound analysis using the s-transforms[J]. Physica A, 1997, 23 (9): 286-295.
  • 10Mansinha L, Stockwell R G, Lowe R P. Pattern analysis with two dimensional spectral localization: application of two-dimensional S-transform[J]. Physica A, 1997, 23 (9): 286-295.

二级参考文献52

共引文献124

同被引文献205

引证文献14

二级引证文献119

;
使用帮助 返回顶部