期刊文献+

二滩水电站水轮机差压法流量测量 被引量:5

Differential pressure method on flow measurement in Ertan Hydraulic Power Station
下载PDF
导出
摘要 水轮机过机流量准确测量,对促进水电机组经济运行、指导水电厂生产管理具有重要意义。基于现场条件,根据理论推导和计算结果,在二滩电站用很小的花费实现了差压法过机流量测量;根据实践经验,对现场测流容易碰到的问题和解决办法进行了总结。 Accurate measurement of turbine discharge is important for enhancing economic operation of hydroelectric generatingset and directing production management of hydroelectric power plant. With the condition on site, based on theoretical derivationand computing result, using differential pressure method to measure turbine discharge is realized by low cost in Ertan HydraulicPower Station; According to practical experience, the problems in measurement and the solutions are summarized.
作者 徐文峰
出处 《水电站机电技术》 2011年第4期25-27,64,共3页 Mechanical & Electrical Technique of Hydropower Station
关键词 二滩水电站 水轮机 流量测量 压差 Ertan Hydraulic Power Station hydraulic turbine flow measurement differential pressure