摘要
针对300 MW CFB锅炉水冷壁防磨防爆问题,从治理前状况、运行防磨防爆措施、防磨防爆技改措施、防磨防爆取得的效果和结论等方面进行了阐述。
In view of the existing explosion and wearing protection problems of water wall of 300 MW CFB boiler,situation before renovation,operation and renovation measures of explosion and wearing protection,conclusions and effect of explosion and wearing protection were discussed in the paper.
出处
《华北电力技术》
CAS
2011年第10期26-30,共5页
North China Electric Power
关键词
CFB锅炉
水冷壁
防磨防爆
运行调整
技术改造
CFB boiler
water wall
explosion and wearing protection
operation governing
renovation