期刊文献+

纸机干燥部多段通汽系统中喷射式热泵的性能分析 被引量:14

Performance Analysis of Ejector Heat Pump for Multistage Drying System of Paper Machine
下载PDF
导出
摘要 提出纸机干燥部多段通汽系统中喷射式热泵的性能参数计算方法 ,编制出适应纸机特点的喷射式热泵性能分析与结构设计软件 ,给出了喷射式热泵的工作范围与调节特性的计算分析结果。据此在纸机干燥部多段通汽系统中设置喷射器 ,组成热泵系统 ,可明显提高烘缸排水能力 ,降低造纸成本。 The effects of enhanced expelling condensate from drying cylinder and reducing steam consumption are achieved by installing ejector heat pumps in multistage drying section of paper machine. This paper presents the performance analysis method of ejector heat pump in multistage drying system. The software for ejector performance analysis and geometry calculation is established. With the software the working range and adjustment characteristic of ejectors are analyzed.
出处 《中国造纸》 CAS 北大核心 2000年第2期36-40,共5页 China Pulp & Paper
关键词 纸机 干燥部 热泵 节能 多段通气系统 paper machine,drying section,heat pump,energy conservation
  • 引文网络
  • 相关文献

参考文献3

  • 1Huang M. and Chen S.. An experimental investigation of ejectorperformance characteristics in a jet refigeration system. J. of the Chin.I.Ch.E., Vol.27,No.2, pp.91~100,1996
  • 2Eames I.W. Aphornratana S. and Haider H.. A theoretical and experimental study of asmall-scale steam jet refrigerator. Int.J.Refrig., Vol.18, No.6, pp.378~386,1985
  • 3Sokolov M. and Hersiigal D.. Optimal coupling and feasibility of a solorpoweredyear-round ejector air conditioner. Solar Energy, 1993,50(60):507~516

同被引文献87

引证文献14

二级引证文献64

;