期刊文献+

利用VM-7衰减校准系统实现微波阻抗参量测试

Developing calibration of microwave impedance with VM-7 attenuator calibrating system
下载PDF
导出
摘要 通过对VM-7衰减校准系统的构成原理及阻抗参量测试方法的分析研究,充分利用其动态范围宽、灵敏度高、频率范围宽等显著优点,提出了利用VM-7衰减校准系统结合驻波比电桥来实现微波阻抗参量测试的方案,对构造原理、实现过程和测量结果的不确定度分析进行了详细介绍。经过实测验证:系统稳定性好、准确度高,可为微波阻抗参量的计量测试提供一套切实可行的解决方案。 By analyzing the theory of the VM-7 attenuator calibrating system and the traditional calibration method of microwave impedance,the authors develop a method to calibrate the microwave impedance with VM-7 attenuator calibrating system.This method fully takes the advantages of VM-7 such as wide dynamic range,high sensitivity,wide frequency range,and so on.Details of construction principle,implementation process and measurement uncertainty evaluation were introduced.The developed method has good stability and high accuracy,which is proven by the actual test results.It can be a set of practical solutions to the calibration of microwave impedance.
机构地区 [
出处 《中国测试》 CAS 北大核心 2012年第2期39-41,共3页 China Measurement & Test
关键词 VM-7系统 衰减 阻抗 校准 测试 VM-7 attenuator impedance calibrate test
  • 相关文献

参考文献4

二级参考文献9

  • 1冯新善.无线电基本参量[M].北京:中国计量出版社,1987..
  • 2冯新善,高频.微波功率的计量测试[M].北京:中国计量出版社.1987年.
  • 3JJF1059-1999.测量不确定度评定与表示[S].[S].,..
  • 4国家质量技术监督局计量司.测量不确定度评定与表示指南[M].北京:中国计量出版社,2000.29-44.
  • 5冯新善.高频、微波衰减的计量测试.北京:中国计量出版社,1987年
  • 6冯新善.无线电基本参量.北京:中国计量出版社,1987年
  • 7汤世贤.微波测量.北京:国防工业出版社,1991年
  • 8JJG321-83,串联高频替代法检定衰减器[S].
  • 9冯新善.无线电基本参量[M].北京:中国计量出版社,1987.

共引文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部