期刊文献+

过电压限制下分布式光伏电源最大允许接入峰值容量的计算 被引量:56

Peak Capacity Calculation of Distributed Photovoltaic Source with Constraint of Over-voltage
下载PDF
导出
摘要 在传统配电网中接入分布式光伏电源会带来诸多不利因素,如可能导致接入点处过电压,因此,必须限制分布式光伏电源实际接入峰值容量。通过计算在配电网馈线上所有负荷等级下分布式光伏电源的最大允许输出功率及采用相关观测数据,可大致计算出分布式光伏电源的最大允许接入峰值容量,将分布式光伏电源的实际接入峰值容量控制在最大允许接入峰值容量内,一般可避免接入点处出现过电压现象。当配电网馈线离满载运行还有一定余量时,分布式光伏电源按超前功率因数运行,可提高最大允许接入峰值容量,从而提高分布式光伏电源在配电网中的渗透率。 The interconnection of distributed photovoltaic source(DPVS) may have adverse impacts on the traditional distribution network,such as over-voltages at the grid coupling point,so it is necessary to limit the on-grid peak capacity of DPVS.The maximum allowable capacity of DPVS under constraint of over-voltage is calculated with the yearly historical data.The over-voltage phenomenon is avoided by limiting the capacity of DPVS under maximum allowable figure.When the feeder is operating at a partial loading level,the allowed capacity of DPVS in the distribution network can be enhanced by operating DPVS with a leading power factor.
出处 《电力系统自动化》 EI CSCD 北大核心 2012年第17期40-44,共5页 Automation of Electric Power Systems
基金 国家高技术研究发展计划(863计划)资助项目(2009AA05Z221)~~
关键词 分布式电源 光伏发电 过电压 光伏模块 峰值容量 渗透率 超前功率因数 distributed power source photovoltaic source over-voltage photovoltaic module peak capacity permeability leading power factor
  • 相关文献

参考文献4

二级参考文献26

共引文献344

同被引文献504

引证文献56

二级引证文献670

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部