期刊文献+

三维柔性阵列触觉传感器结构设计 被引量:5

Structure design method of a three-dimensional flexible tactile sensor arrays
下载PDF
导出
摘要 为减少类皮肤三维柔性触觉阵列传感器设计的复杂度,本文比较了基于导电橡胶的几种传感器结构设计方法,提出了采用整体式框架结构,节点行之间独立的非线性传感器结构。此设计不仅有利于传感器结构的加工实现,而且大大地降低了解耦算法的复杂度。仿真结果表明基于该结构的传感器可以实现大规模三维柔性触觉的信息测量以及传感器规模的扩展。 In order to reduce the design complexity of the skin liked large-scale 3-D flexible tactile sensor arrays, this paper compared several structure design methods of sensor based on conductive rubber. A unique nonlinear structure with each row of upper nodes layer independent to other rows is proposed. The structure is beneficial for sensor manu- facture technology, greatly reduces the complexity of the decoupling algorithm. Simulation results show that the sensor based on this structure can achieve flexible measurement of large-scale 3-D tactile arrays and the arrays size can be expended easily.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 2012年第12期2721-2727,共7页 Chinese Journal of Scientific Instrument
基金 国家自然基金面上项目(61072032)资助
关键词 柔性 触觉传感器 结构 解耦算法 flexible tactile sensor structure decoupling algorithm
  • 相关文献

参考文献13

二级参考文献58

共引文献70

同被引文献58

  • 1李秀娟,许湘剑.一种采用光波导的触觉传感器[J].仪器仪表学报,2002,23(z1):127-129. 被引量:8
  • 2明小慧,黄英,向蓓,葛运建.三维力柔性触觉传感器设计[J].华中科技大学学报(自然科学版),2008,36(S1):137-141. 被引量:3
  • 3YANG Y. A 32 x 32 temperature and tactile sensing ar- ray using PI-copper films [ J ]. The International Journal of Advanced Manufacturing Technology, 2010 ( 46 ) : 946-956.
  • 4SHIH W. Flexible temperature sensor array based on a Graphite-Polydimethylsiloxane composite [ J ]. Sensors,2010, 4(9) : 3597-3610.
  • 5MATTAR E. A survey of bio-inspired robotics hands implementation: new directions in dexterous manipula- tion [ J]. Robotics and Autonomous Systems, 2013: 517-544.
  • 6CHENG M. The development of a highly twistable tact- ile sensing array with stretchable helical electrodes [ J ]. Sensors and Actuators A: Physical, 2011: 226-233.
  • 7LAI Y. A tactile sensing array with tunable sensing ran- ges using liquid crystal and carbon nanotubes composites [ J]. Sensors and Actuators A : Physical, 2012 : 48-53.
  • 8ALVARESA D. Development of nanoparticle film- based multi-axial tactile sensors for biomedical appli- cations [ J ]. Sensors and Actuators A: Physical, 2013 : 38-47.
  • 9SCANDURRA G. Low temperature gas sensing applica- tions using copier grade transparency sheets as substrates [ J ]. Sensors and Actuators B: Chemical, 2011: 473-481.
  • 10PEDRO S. Tactile sensors for robotic applications [ J ]. Measurement, 2013, 1257-1271.

引证文献5

二级引证文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部