期刊文献+

Study of the Retinal Imaging and Output in Premature Baby under a Computer-assisted Binocular Indirect Ophthalmoscope 被引量:3

Study of the Retinal Imaging and Output in Premature Baby under a Computer-assisted Binocular Indirect Ophthalmoscope
下载PDF
导出
摘要 Purpose:To explore a clear retinal imaging and output and enhance the development of retinopathy of prematurity (ROP) screening,which is safe and effective for ROP screening in premature infants. Methods:A computer-assisted binocular indirect ophthalmoscope imaging and output system was equipped with camera and image processing hardware and connected to computers. The process of fundus examination was videotaped (photograph) and output. Simulated eyes were utilized to debug video head and acquire stable and clear fundus images by binocular indirect ophthalmoscope for premature infants. Results:Fundus imaging output technique was sucessfully established. The common reasons of unclear imaging and corresponding solutions were summarized. This technique can capture and output stable and clear fundus images of premature infants. Conclusion: Assisted by hardware and software processing, a compute assisted binocular indirect ophthalmoscope imaging and output system was established,which can be used for screening, research, treatment and follow-up of ROP in premature babies to resolve the difficulty in obtaining clear fundus photograph. Purpose: To explore a clear retinal imaging and output and enhance the development of retinopathy of prematurity (ROP) screening, which is safe and effective for ROP screening in premature infants. Methods: A computer-assisted binocular indirect ophthalmoscope imaging and output system was equipped with camera and image processing hardware and connected to computers. The process of fundus examination was videotaped (photo- graph) and output. Simulated eyes were utilized to debug video head and acquire stable and clear fundus images by binocular indirect ophthalmoscope for premature infants. Results: Fundus imaging output technique was sucessfully es- tablished. The common reasons of unclear imaging and corre- sponding solutions were summarized. This technique can capture and output stable and clear fundus images of premature infants. Conclusion: Assisted by hardware and software processing, a compute assisted binocular indirect ophthalmoscope imaging and output system was established, which can be used for screening, research, treatment and follow-up of ROP in pre- mature babies to resolve the difficulty in obtaining clear fundus photograph.
出处 《Eye Science》 CAS 2012年第4期210-214,共5页 眼科学报(英文版)
基金 Guangzhou Science and Technology Program(2012Y2-00017) Guangdong Provincial Science and Technology Projects (83036) Guangdong Provincial Natural Science Fund(82011010004440)
关键词 输出技术 早产儿 视网膜 计算机辅助 成像 间接 眼镜 计算机硬件 binocular indirect ophthalmoscope cumputer-assisted fundus imaging
  • 相关文献

参考文献5

二级参考文献43

共引文献39

同被引文献31

引证文献3

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部