摘要
针对蜀河水电厂灯泡贯流式机组的特点,结合辅助设备及厂用电系统的生产实际,对可能造成机组断油烧瓦事故的原因分析,并提出了应对措施,延长了径向瓦的使用寿命。
Aiming at characteristics of bulb tubular unit applied by Shuhe Hydropower Station and in combination with actualities of auxiliary equipment and service power system, causes which may result in occurrence of bush burnt from lubricant lack are analyzed as well as corresponding countermeasures are raised so as to extend service life of radial bush.
出处
《西北水电》
2012年第6期62-64,共3页
Northwest Hydropower
关键词
轴承
轴瓦
润滑油系统
断油烧瓦
灯泡贯流式机组
蜀河水电站
bearing
bush
lubricant system
bush burnt from lubricant lack
bulb tubular unit
Shube Hydropower Station