期刊文献+

迭代重建在前列腺CT成像中的应用研究 被引量:1

Application of iterative reconstruction in CT imaging of the prostate
下载PDF
导出
摘要 目的:探讨迭代重建在前列腺CT检查中的临床应用价值。方法:接受腹部CT增强扫描的男性患者4例入组,对增强图像进行滤波反投影重建(FBP)、30%、50%、80%及100%自适应统计迭代重建(ASIR)和基于模型的迭代重建(MBIR),对这6种图像的噪声、图像质量、前列腺对比噪声比(CNR),使用方差分析进行统计学分析。结果:MBIR图像的噪声最低,主观评分最高,且前列腺外周带的CNR最高,与其它图像相比差异有统计学意义(P<0.05)。结论:MBIR有提高前列腺图像质量、进一步显示更多解剖细节的潜在价值。 Objective:To explore the value of adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) in improving prostate imaging. Methods:Four male patients receiving abdominal CT examination with contrast enhancement were enrolled. The enhanced images were reconstructed with filter back projection,30%, 50% ,80% and 100%ASIR and MBIR algorithm respectively. And the image noises were measured. Contrast-to-noise ratio (CNR)of prostate was assessed. Image quality was assessed using a 6-point scale. Results: The image noise of MBIR was the lowest, and the image quality and the CNR of peripheral zone were the highest. Conclusion: MBIR has potential ability in improving image quality of the prostate in the future.
出处 《放射学实践》 2013年第3期284-287,共4页 Radiologic Practice
关键词 体层摄影术 X线计算机 前列腺病变 迭代重建 辐射剂量 Tomography,X-ray computed Prostate diseases Iterative reconstruction Radiation dose
  • 相关文献

参考文献1

二级参考文献8

  • 1Kalra MK,Maher MM,Toth TL,et al.Strategies for CT radia-tion dose optimization.Radiology,2004,230(3):619-628.
  • 2Heyer CM,Mohr PS,Lemburg SP,et al.Image quality and ra-diation exposure at pulmonary CT angiography with 100-or 120-kVp protocol:Prospective randomized study.Radiology,2007,245(2):577-583.
  • 3Kalra MK,Wittram C,Maher MM,et al.Can noise reductionfilters improve low-radiation-dose chest CT images?Pilot study.Radiology,2003,228(1):257-264.
  • 4Marin D,Nelson RC,Schindera ST,et al.Low-tube-voltage,high-tube-current multidetector abdominal CT:Improved imagequality and decreased radiation dose with adaptive statistical itera-tive reconstruction algorithm--initial clinical experience.Radiolo-gy,2010,254(1):145-153.
  • 5Pan X,Sidky EY,Vannier M.Why do commercial CT scannersstill employ traditional,filtered back-projection for image recon-struction?Inverse Probl,2009,25(12):1230009.
  • 6Knesaurek K,Machac J,Vallabhajosula S,et al.A new iterativereconstruction technique for attenuation correction in high-resolu-tion positron emission tomography.Eur J Nucl Med,1996,23(6):656-661.
  • 7Wells RG,King MA,Simkin PH,et al.Comparing filteredbackprojection and ordered-subsets expectation maximization forsmall-lesion detection and localization in 67Ga SPECT.J NuclMed,2000,41(8):1391-1399.
  • 8Riddell C,Carson RE,Carrasquillo JA,et al.Noise reduction inoncology FDG PET images by iterative reconstruction:A quanti-tative assessment.J Nucl Med,2001,42(9):1316-1323.

共引文献55

同被引文献5

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部