摘要 为了研究增设抗震墙加固既有单跨框架时需设墙体的合理数量,以单跨框架的层数及刚度特征值为参数,采用解析方法,讨论了加固前后原框架地震剪力变化.结果表明:在选取最优刚度特征值的情况下,当总层数n=4时,原框架结构第4层抗剪承载力缺口为3.4%~4.4%;当总层数n=8时,原框架结构第8层抗剪承载力缺口为11.7%~12.8%;当总层数n=12时,原框架结构第12层抗剪承载力缺口为14.4%~15.7%、第11层抗剪承载力缺口为4.3%~5.2%.由此可得,原框架顶部楼层进行加固不可避免、原框架总层数越多顶部需加固的楼层数越多且相应楼层框架抗剪承载力缺口越大、最优刚度特征值为1.0~1.2等. Aiming at studying the reasonable number of shear walls utilized to strengthen single-bay frame structure, the storey number and stiffness characteristic coefficient of the structure are selected as parameters to investigate the variation of the frame shear force before and after being reinforced. The results show that, with the optimal stiffness characteristic coefficient, if the storey number n = 4, the shear capacity of the 4th floor lacks 3.4% to 4.4% ; if n = 8, the shear capacity of the 8th floor lacks 11.7% to 12.8% ; if n = 12, the shear capacity of the 12th floor lacks 14.4% to 15.7%, and that of the llth floor lacks 4.3% to 5.2%. Therefore, the upper floor of the single- bay structure needs strengthening inevitably. The number of stories need reinforcing and the shear capacity gap of the upper floor increase with the increase of the storey number of the structure. The optimal stiffness characteristic coefficient is 1.0 to 1.2.
出处 《东南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2012年第A02期336-339,共4页 Journal of Southeast University:Natural Science Edition
关键词 单跨框架 抗震墙 加固 层数 刚度特征值 水平地震作用 single-bay frame shear wall strengthening storey number stiffness characteristic co-efficient horizontal earthquake force
  • 相关文献

参考文献11

  • 1段贵明,史铁花.单跨框架结构抗震加固方法研究[J].建筑结构,2010,40(5):72-73. 被引量:18
  • 2吴善能,汤翔.几种单跨框架结构抗震加固方法的比较[J].四川建筑科学研究,2012,38(4):160-164. 被引量:13
  • 3张令心,王财权,刘洁平.翼墙加固方法对框架结构抗震性能的影响分析[J].土木工程学报,2012,45(S2):16-21. 被引量:11
  • 4Erdem I, Akyuz U, Ersoy U, et al. An experimental study on two different strengthening techniques for RC frames [ J ]. Engineering Structures, 2006, 28 ( 13 ) : 1843 - 1851.
  • 5Kaplan Hasan, Yilmaz Salih, Cetinkaya Nihat, et al. Seismic strengthening of RC structures with exterior shear walls [ J ]. Sadhana-Academy Proceedings in En- gineering Sciences, 2011, 36( 1 ) : 17 -34.
  • 6Baran M, Okuyucu D, Susoy M, et al. Seismic strengthening of reinforced concrete frames by precast concrete panels [ J ]. Magazine of Concrete Research, 2011, 63(5): 321-332.
  • 7Gokce Kurt E, Kurc O, Binici B, et al. Performance examination of two seismic strengthening procedures by pseudo dynamic testing [ J ]. Journal of Structural Engi- neering, 2012, 138(1): 31-41.
  • 8中华人民共和国住房和城乡建设部.JGJ3-2010高层建筑混凝土结构技术规程[S].北京:中国建筑工业出版社,2010.
  • 9刘开国.框-剪结构抗震剪力墙数量的优化[J].建筑结构,1999,29(2):15-16. 被引量:12
  • 10邱洪兴.建筑结构设计[M].北京:高等教育出版社.2012.

二级参考文献16

  • 1国明超,栾曙光,鞠杨,李炳益.钢筋混凝土带翼墙短柱抗震性能研究[J].建筑结构学报,1996,17(3):32-42. 被引量:10
  • 2王全风.框架-剪力墙高层建筑抗震荷载剪力墙数量的优化分析[J].土木工程学报,1983,(3).
  • 3GB50023-2009,建筑抗震鉴定标准[S].
  • 4JGJll6-2009,建筑抗震加固技术规程[S].
  • 5GB50011-2010,建筑抗震设计规范[S].
  • 6刘开国,结构简化计算原理及其应用,1996年
  • 7贺友双,工程抗震,1992年,1期
  • 8赵西安,钢筋混凝土高层建筑结构设计与施工规程(JGJ3-91),1991年
  • 9江爱川,结构优化设计,1986年
  • 10王全风,土木工程学报,1983年,3期

共引文献94

同被引文献13

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部