摘要
基于天津市室外逐时气象参数,利用了能耗分析软件Dest,以天津地区为例,针对室内排风显热与全热热回收系统,就其节能量与季节、室内温度、相对湿度等因素的相关性进行了量化研究和分析,为此类系统的设计提供了依据。
According to the hourly meteorological parameters of Tianjin, Dest is applied to quantitatively analyze the correlation between energy saving and seasonal change, indoor temperature, relative humidity when using sensible heat or total heat recovery system. The result is using as references for the design of these two systems.
出处
《洁净与空调技术》
2013年第2期88-90,共3页
Contamination Control & Air-Conditioning Technology
关键词
热回收
显热
全热
量化分析
Heat recovery
Sensible heat
Latent heat
Quantitatively analyze