摘要
从运行方式着手 ,对 10kV双回电力线路完全同杆和不完全同杆架设方式的经济运行情况进行分析对比 ,探讨 10kV配电网降损节能的新途径 ,为目前城市。
In this paper, a comparison on economic operation is made between complete joint use and incomplete joint use modes of 10 kV double circuit line. It is concluded that the former is of much greater advantage for lowering line losses.
出处
《广东电力》
2000年第4期41-42,69,共3页
Guangdong Electric Power
关键词
电力线路
架设方式
经济运行
10kV power line
line construction modes
economic operation